期刊文献+

Accuracy of two optical chlorophyll meters in predicting chemical composition and in vitro ruminal organic matter degradability of Brachiaria hybrid,Megathyrsus maximus, and Paspalum atratum

Accuracy of two optical chlorophyll meters in predicting chemical composition and in vitro ruminal organic matter degradability of Brachiaria hybrid,Megathyrsus maximus, and Paspalum atratum
原文传递
导出
摘要 The objective of this study was to determine the accuracy and reliability of 2 optical chlorophyll meters:FieldScout CM 1,000 NDVI and Yara N-Tester, in predicting neutral detergent fibre(NDF), acid detergent fibre(ADF), acid detergent lignin(ADL), acid detergent insoluble nitrogen(ADIN) and in vitro ruminal organic matter degradability(IVOMD) of 3 tropical grasses. Optical chlorophyll measurements were taken at 3 stages(4, 8 and 12 weeks) of regrowth in Brachiaria hybrid, and Megathyrsus maximus and at 6 and 12 weeks of regrowth in Paspalum atratum(cv. Ubon). Optical chlorophyll measurements showed the highest correlation(r = 0.57 to 0.85) with NDF concentration. The FieldScout CM 1,000 NDVI was better than the Yara N-Tester in predicting NDF(R^2 = 0.70) and ADF(R^2 = 0.79) concentrations in Brachiaria hybrid and NDF(R^2 = 0.79) in M. maximus. Similarly, FieldScout CM 1,000 NDVI produced better estimates of 24 h IVOMD(IVOMD_(24 h)) in Brachiaria hybrid(R^2 = 0.81) and IVOMD_(48 h) in Brachiaria hybrid(R^2 = 0.65) and M. maximus(R^2 = 0.75). However, these prediction models had relatively low concordance correlation coefficients, i.e., CCC >0.90, but random errors were the main source of bias. It was,therefore, concluded that both optical chlorophyll meters were poor and unreliable predictors of ADIN and ADL concentrations. Overall, the FieldScout CM 1,000 NDVI shows potential to produce useful estimates of IVOMD_(24h) and ADF in Brachiaria hybrid and IVOMD_(48 h) and NDF concentrations in M. maximus. The objective of this study was to determine the accuracy and reliability of 2 optical chlorophyll meters:FieldScout CM 1,000 NDVI and Yara N-Tester, in predicting neutral detergent fibre(NDF), acid detergent fibre(ADF), acid detergent lignin(ADL), acid detergent insoluble nitrogen(ADIN) and in vitro ruminal organic matter degradability(IVOMD) of 3 tropical grasses. Optical chlorophyll measurements were taken at 3 stages(4, 8 and 12 weeks) of regrowth in Brachiaria hybrid, and Megathyrsus maximus and at 6 and 12 weeks of regrowth in Paspalum atratum(cv. Ubon). Optical chlorophyll measurements showed the highest correlation(r = 0.57 to 0.85) with NDF concentration. The FieldScout CM 1,000 NDVI was better than the Yara N-Tester in predicting NDF(R^2 = 0.70) and ADF(R^2 = 0.79) concentrations in Brachiaria hybrid and NDF(R^2 = 0.79) in M. maximus. Similarly, FieldScout CM 1,000 NDVI produced better estimates of 24 h IVOMD(IVOMD_(24 h)) in Brachiaria hybrid(R^2 = 0.81) and IVOMD_(48 h) in Brachiaria hybrid(R^2 = 0.65) and M. maximus(R^2 = 0.75). However, these prediction models had relatively low concordance correlation coefficients, i.e., CCC >0.90, but random errors were the main source of bias. It was,therefore, concluded that both optical chlorophyll meters were poor and unreliable predictors of ADIN and ADL concentrations. Overall, the FieldScout CM 1,000 NDVI shows potential to produce useful estimates of IVOMD_(24h) and ADF in Brachiaria hybrid and IVOMD_(48 h) and NDF concentrations in M. maximus.
出处 《Animal Nutrition》 SCIE 2017年第1期67-76,共10页 动物营养(英文版)
基金 the University of the West Indies and the Jamaica Dairy Development Board for providing financial support to undertake this research
关键词 Optical chlorophyll measurements Chemical composition Prediction model Tropical grass Optical chlorophyll measurements Chemical composition Prediction model Tropical grass
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部