期刊文献+

庐江台人工测氡与数字化自动测氡对比分析研究 被引量:12

The comparison study between artificial and digital observation of Radon in Lujiang station of Anhui province
下载PDF
导出
摘要 以安徽庐江台观测资料为基础,分析数字化测氡与人工取样测氡结果的精度、相关性、影响因素等。数字化测氡观测精度高,但受气温、气压影响较大;气氡与水氡资料动态特征有较大差异,数字化气氡值与人工测气氡、人工测水氡不相关,水气Rn/Rn与井水温成正比。由于数字化测氡观测时间较短,资料又非常有限,还缺少一定的震例,因此,在一定时间内数字化测氡与人工测水氡应同时进行。 Based on the artifical and digital observation data of Radon in Lucian station, we have analyzed precision, relativity and influencing factors of the observation results. Digital observation data have higher precisiom and influence of the temperature and atmosphere. The change characteristics of gaseous Radon is different to that of water Radon. The observation valus of the digital gaseous Radon isn抰 correlated with the values of the artificial gaseous and water Radon. The ratio of Radon(gas) to Radon (water) is directly proportional to the water temperature. Consequently, the digital observation and artificial ovbservation should go togher for a long time.
出处 《地震地磁观测与研究》 2002年第3期26-32,共7页 Seismological and Geomagnetic Observation and Research
基金 安徽省地震局的大力资助
关键词 气氡 水氡 数字化 人工观测 对比分析 气温 气压 地震前兆 escaped Radon,water Radon,digitalization,artificial,comparison analysis