期刊文献+

电压稳定极限曲面法向量在无功补偿选址中的应用 被引量:2

Application of Normal Vector of Voltage Stability Limit Surface in Reactive Power Compensation Allocation
下载PDF
导出
摘要 合理地选择无功补偿装置的安装地点对于提高电力系统电压稳定性有重要意义。针对传统的失稳模式参与因子选址方法的局限性,提出了一种基于节点注入功率空间中电压稳定极限曲面的法向量指标用于无功补偿选址,并通过理论分析证明了法向量指标指导无功补偿的合理性。对IEEE39节点系统测试结果表明,与传统方法相比,法向量指标可以处理鞍结分岔和极限诱导分岔两类电压稳定临界点情况下的无功补偿选址,具有更大的适用范围。 Proper reactive power compensation allocation is important to enhance the power system voltage stability. Based on the limitation of the traditional participation factor based allocation method, a normal vector index based on voltage stability limit surface is proposed to reactive power compensation allocation in this paper. The rationality of the index is proved. Simulation results on IEEE39 system have validated the correctness of the proposed index. Compare with the traditional method, the proposed index has a wider range of application since it can deal with the voltage stability critical point of saddle node bifurcation or limit induced bifurcation.
出处 《水电能源科学》 北大核心 2014年第6期157-160,共4页 Water Resources and Power
基金 上海市优秀学术带头人计划项目(12XD1402900)
关键词 电压稳定极限曲面 节点注入功率空间 鞍结分岔 极限诱导分岔 无功补偿 电压稳定裕度 voltage stability limit surface injection power space saddle node bifurcation limit induced bifurcation reactive power compensatiom voltage stability margin
  • 相关文献

参考文献8

  • 1Li H,Jin Y,Cheng H. A Novel Reactive Power Planning Based on Improved Particle Swarm Optimization with Static Voltage Stability[J]. European Transac- tions on Electric Power,2010,20:1 129-1 137.
  • 2Song S H,Lim J U,Moon S I. Installation and Op- eration of FACTS Devices for Enhancing Steady- state Security[-J]. Electric Power Systems Research, 2004,70(1) :7-15.
  • 3Gao B, Morison G K, Kundur P. Voltage Stability E- valuation Using Modal Analysis[J]. IEEE Transac-tions on Power Systems,1992,7(4):1 529-1 542.
  • 4Mansour Y, Xu W, Alvarado F, et al. SVC Place- ment Using Critical Modes of Voltage Instability [J]. IEEE Transactions on Power Systems, 1994,9 (2):757-763.
  • 5张靖,程时杰,文劲宇,彭志炜.通过选择SVC安装地点提高静态电压稳定性的新方法[J].中国电机工程学报,2007,27(34):7-11. 被引量:37
  • 6Dobson I, Lu L M. Computing an Optimum Direc- tion in Control Space to Avoid Stable Node Bifurca- tion and Voltage Collapse in Electric Power Systems [J]. IEEE Transactions on Automatic Control, 1992,37(10).,1 616-1 620.
  • 7熊宁,程浩忠,马则良,朱忠烈,王晓辉,陆建忠.基于连续潮流的极限诱导分岔检测方法[J].电力系统自动化,2008,32(18):35-38. 被引量:14
  • 8Kataoka Y,Shinoda Y. Voltage Stability Limit of E- lectric Power Systems with Generator Reactive Power Constraints Considered [J]. IEEE Transac- tions on Power Systems,2005,20(2) :951-962.