1NKF-KDOQI. Clinical practice guidelines for vascular ac- cess: update July 2006[J]. Am J Kidney Dis, 2006,48 (Suppl 1) :S187-S277.
2Twardowski Z, Kubara H. Different sites versus constant sites of needle insertion into arteriovenous fistula for treatment by repeated hemodialysis[J]. Dial Transplant, 1979,8(10) : 978-980.
3Kronung G. Plastic deformation of Cimino fistula by re- peated puncture[J]. Dial Transplant, 1984,13 (10) : 635- 638.
4Ball L K. The buttonhole technique for arteriovenous fis- tula cannulation[J]. Nephrol Nurs J, 2006,33 ( 3 ): 299- 304.
2Amano I, Ohira S, Goto Y, et al. In preparation for a treatment guideline for suitable vascular access repair in Japan [J]. Therapeutic Apheresis and Dialysis,2006,10(4) :364-371.
4NKF-K/DOQI. Clinical practice guidelines for vascular access: update July 2006[J]. Am J Kidney Dis,2006,48:S187-S277.
5Toma S, Fukui H, Nakai S, et al. A timesaving method to create a fixed puncture route for the buttonhole teehnlque[J]. Nephrel Dial Transplant, 2003,18:2118-2121.
6NKF-K/DOQI.Clinical practice guidelines for vascular access:update July 2006.Am J Kidney Dis,2006,48:187-207.
9Toma S,Fukui H,Nakai S,et al.A timesaving method to create a fixed puncture route for the buttonhole technique.Nephrol Dial Transplant J,2003,18:2118-2121.
10NKF-K/DOQI. clinical practice guidclines for vascular access : up- date July 2006. am J Kidney/9is,2006,48 (3) :s187-s277.
2National Kindey Foundation. KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates : Hemo- dialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access [ J ]. Am J Kidney Dis,2006,48 (suppl 1 ) :176-270.
3Castro MC, Silva CdeF, Souza JM, et al. Arteriovenous fistula can- nulation by buttonhole technique using dull needle [ J ]. J Bras Nefrol,2010,32( 3 ) :281-285.
4Van Loon MM, Goovaerts T, Kessels AG, et al. Buttonhole nee- dling of haemodialysis arteriovenous fistulae results in less compli- cations and interventions compared to the rope-ladder technique [ J]. Nephro Dialy Transplantat ,2009,25 ( 1 ) :225-230.
5Galante NZ, Rabelo LL, Yamamoto A, et al. One unit's experi- ences when establishing buttonhole technique, analysis of reasons for failure of procedure : a report [ J ]. J Renal Care,2010,36 ( 2 ) : 73-80.
6Ball LK, Mott S. How do you prevent indented button hole sites [J]. Nephrol Nuts J,2010,37(4) :427-428,431.
7Donato-Moore S. Buttonhole cannulation technique in a patient with keloid scarred skin on home hemodialysis:a case study[J]. Nephrol Nurs J,2011,38( 1 ) :60-64.
8Mott S, Prowant BF. The "touch cannulation" technique for he- modialysising. Nephrol Nurs J ,2008,35 ( 1 ) :65-66.
9Zasuwa G, Frinak S, Besarab A ,et al. Automated intravascular ac cess pressure surveillance reduces thrombosis rates[J]. Semin Di al,2010,23(5) :527 - 535.
10Marticorena RM, Hunter J, Macleod S, et al. Use of the BioHol eTM device for the creation of tunnel tracks for buttonhole cannu lation of fistula for hemodialysis[J]. Hemodial Int,2011,15(2) 243 - 249.