基于二阶网损无功灵敏度矩阵的配电网无功补偿选点 被引量:32

Optimal Location of Reactive Power Compensation for Distribution Network Based on Second Order Loss-Reactive Power Sensitivity Matrix
下载PDF
导出
摘要 目前配电网无功优化规划多采用灵敏度分析等方法来确定配电网无功补偿点。传统的灵敏度分析方法以补偿前节点灵敏度来选择补偿点,依赖补偿前网络潮流,选出的点容易集中在重负荷支路,导致补偿范围重叠,无功补偿可能并非最优。为此,提出了二阶网损无功灵敏度矩阵的计算方法,并基于此提出了配电网无功补偿选点方法,考虑了后选补偿节点补偿容量对先选补偿节点灵敏度的影响。算例结果验证了该方法的有效性。 At present, in the reactive power optimization planning for distribution network the methods such as sensitivity analysis and so on are utilized to determine the location, where reactive power compensation devices are installed. In traditional sensitivity analysis method the pre-compensation nodal sensitivity is used to choose the location for reactive power compensation, so it depends on the pre-compensation power flow and the chosen compensation locations are frequently concentrated upon the branches with heavy load, and it leads to the overlap of compensation ranges and possibly the effect of reactive power compensation is not the optimal. For this reason, a method to calculate the second order network-loss reactive power sensitivity matrix is proposed, and on this basis a new method to choose the location for reactive power compensation in distribution network is given, in which the impacts of the compensation capacity of the compensation node selected in the latter on the sensitivity of the compensation node selected in the former are considered. The effectiveness of the proposed method is validated by simulation results of a 28-bus distribution network.
出处 《电网技术》 EI CSCD 北大核心 2014年第7期1979-1983,共5页 Power System Technology
基金 国家自然科学基金项目(51307038) 浙江省自然科学基金项目(LZ12E07001)~~
关键词 二阶网损无功灵敏度矩阵 灵敏度分析 配电网 无功补偿 无功补偿选点 second order network-loss reactive power sensitivity matrix sensitivity analysis distribution network reactive power compensation location selection of reactive power compensator
  • 相关文献

参考文献15

二级参考文献143

共引文献256

同被引文献380

引证文献32

二级引证文献236

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部