迭代统计重建在CT结肠成像中降低辐射剂量有效性的体模研究 被引量:3

Efficacy of ASIR for reducing radiation dose in CT colonography:a phantom study
下载PDF
导出
摘要 目的:评价宝石高分辨CT应用不同水平迭代统计重建法(ASIR)在CT结肠成像中降低辐射剂量的有效性。方法选用一段离体猪结肠通过结扎法获得20个5~10 mm的模拟息肉,运用HRCT在不同扫描条件(120 kVp,10、20、30、40、50及100 mAs)下扫描,其中HRCT分别应用6种不同ASIR水平(0、10%、30%、50%、70%及100%)进行数据重建,获得CT仿真内镜、多平面重建和虚拟分割图像。由两名有经验的放射医师采用盲法对不同采集条件、不同ASIR水平的图像进行客观和主观评价,测量并比较平均噪声、平均信噪比(SNR)及平均对比噪声比(CNR),以及结肠息肉的检出率,利用SPSS 16.0统计软件对每组数据进行方差分析。结果结肠模拟息肉模型研究显示不同管电流时HRCT图像噪声均随应用ASIR水平升高而降低,SNR及CNR随应用ASIR水平升高而增高(P<0.05);CT容积剂量指数降低约50%。结论离体模型研究表明在CT结肠成像中,应用ASIR可以显著降低图像噪声,提高信噪比及对比噪声比,从而有效降低辐射剂量。 Objective To evaluate the efficacy of CT colonography with adaptive statistical iterative reconstruction(ASIR)to reduce radiation dose.Methods A series of twenty artificial polyps of 5-10 mm in size were established by ligation in an isolated segment of porcine colon.Volume data were acquired on a High Definition CT scanner at 10,20,30,40,50 and 100 mAs and 120 kVp using six different ASIR levels at 0,10%,30%,50%,70%and 100%.CT virtual endoscopy,multi-planar reformation and virtual dissection models were reconstructed.Two radiologists without knowledge of the polyp location evaluated every image setting. The average noise level,average signal to noise ratio(SNR)and average contrast to noise ratios(CNR)as well as detecting rates of the polyps were calculated and compared statistically among different acquisitions.Results The SNR and CNR progressively increased and the noise decreased with higher percentage of ASIR at every dose level(P〈0.05).CT dosage index was reduced by 50%. Conclusion ASIR significantly reduces image noise and increases SNR and CNR in low-dose CT colonography with improved image quality and lower CT dosage index.
出处 《影像诊断与介入放射学》 2014年第3期195-199,共5页 Diagnostic Imaging & Interventional Radiology
关键词 辐射剂量 图像处理 迭代统计重建法 CT结肠成像 CT容积剂量指数 Radiation dose Image processing Adaptive statistical iterative reconstruction CT colonography CT dosage index
  • 相关文献

参考文献9

  • 1蒋勇,许敏光,仇保跃.宝石HDCT的技术特点与临床应用展望[J].医疗卫生装备,2010,31(1):98-99. 被引量:12
  • 2石明国,杨勇,郑敏文,尤志军,张劲松,彭勇,魏梦琦.新CT新技术——“后64排CT”的发展方向[J].医疗卫生装备,2010,31(1):1-2. 被引量:34
  • 3Thibault JB, Sauer KD, Bouman CA, et al. A three-dimensional statistical approach to improved image quality for multislice heli- cal CT. Med Phys, 2007, 34: 4526-4544.
  • 4Singh S, Kalra MK, Hsieh J, et al. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection recon- struction techniques. Radiology, 2010, 257 : 373-383.
  • 5Flicek KT, Hara AK, Silva AC, et al. Reducing the radiation dose for CT colonography using adaptive statistical iterative recon- struction: A pilot study. Am J Roentgenol, 201 O, 195: 126-131.
  • 6Fisichella VA, Bath M, Allansdotter Johnsson A, et al. Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose. Eur Radiol, 2010, 20: 630-639.
  • 7Pickhardt PJ, Hassan C, Laghi A, et al. Small and diminutive pol- yps detected at screening CT colonography : a decision analysis for referral to colonoscopy. Am J Roentgenol,2008,190: 136-144.
  • 8郭洪涛,刘勇,袁淑华.CT剂量指数(CTDI)测量研究[J].中国测试技术,2007,33(4):33-36. 被引量:33
  • 9Hassan C, Pickhardt PJ, Kim DH, et al. Systematic review : distri- bution of advanced neoplasia according to polyp size at screening colonoscopy. Aliment Pharmacol Ther, 2010, 31 : 210-217.

二级参考文献14

共引文献71

同被引文献39

  • 1袁丹江,杨春梅,黄原义,胡阳.单层螺旋CT最佳图像密度分辨率时扫描参数的探讨[J].医疗装备,2004,17(8):1-3. 被引量:2
  • 2MATHEWS J D, FORSYTHE A V, BRADY Z, et al. Cancer risk in 680, 000 people exposed to computed tomography scans in childhood or adolescence : data linkage study of 11 million Austra- lians[J]. BMJ, 2013, 346(7910): 1-18.
  • 3BENZ M G, BENZ M W, BIRNBAUM S B, et al. Improved spa- tial resolution and lower- dose pediatric CT imaging: a feasibility study to evaluate narrowing the X - ray photon energy spectrum [J]. Pediatr RadioL, 2014, 44(8) : 1026 - 1030.
  • 4RIZZO S, KALRA M, SCHMIDT B, et al. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis[ Jl. AJR Am J Roentgenol, 2006, 186 (3) : 673 - 679.
  • 5STRAUSS K J, GOSKE M J, FRUSH D P, et al. Image Gently Vendor Summit: working together for better estimates of pediatric radiation dose from CT[ J]. AJR Am J Roentgenol, 2009, 192 (5) : 1169 -1175.
  • 6LEE S M, LEE W, CHUNG J W, et al. Effect of kVp on image quality and accuracy in corona~ CT angiography according to pa- tient body size: a phantom study [ J ]. Int J Cardiovasc Imaging, 2013, 29(2) : 83 -9l.
  • 7MOSCAR]ELLO A, TAKX R A, SCHOEPF U J, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image recon- struction technique - comparison with traditional filtered back pro- iection[J]. Eur Radiol, 2011, 21(10) : 2130 -2138.
  • 8SONG J S, LEE J M, SOHN J Y, et al. Hybrid iterative recon- struction technique for liver CT scans for image noise reduction and image quality improvement: evaluation of the optimal iterative re- construction strengths[ J]. Radiol Med, 2014, 120 (3) : 259 - 267.
  • 9BAUMUELLER S, WINKLEHNER A, KARLO C, et al. Low - dose CT of the lung: potential value of iterative reconstructions [J]. EurRadiol, 2012, 22(12) : 2597 -2606.
  • 10HARD1E A D, NELSON R M, EGBERT R, et al. What is the preferred strength setting of the sinogram - affirmed iterative recon- struction algorithm in abdominal CT imaging [ J ]. Radiol Phys Technol, 2014, 8(1): 60-63.

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部