期刊文献+

CT成像造影剂的研究进展 被引量:5

The research progress in CT contrast media
下载PDF
导出
摘要 CT成像已成为临床医学诊断的重要手段,而造影剂是其中重要组成部分。本文对CT成像造影剂的发展简史、应用现状和研究进展作一概要介绍。 CT imaging has become an important means of clinical diagnosis while contrast medium is an important part in CT imaging. In this article, the brief history of the contrast media for CT imaging and their application and research progress are introduced.
作者 刘玉 陶晓峰
出处 《上海医药》 CAS 2014年第13期1-2,7,共3页 Shanghai Medical & Pharmaceutical Journal
基金 国家自然科学基金资助项目(编号:81272802) 上海青年医师培养资助计划资助项目
关键词 CT成像 造影剂 放射学 CT imaging contrast media radiology
  • 相关文献

参考文献13

  • 1Gavant ML, Ellis JV, Klesges LM, et al. Diagnostic efficacy of excretory urography with low-dose, nonionic contrast media [J]. Radiology, 1992, 182(3): 657-660.
  • 2Gharekhanloo F, Torabian S. Comparison of allergic adverse effects and contrast enhancement between iodixanol and iopromide [J]. Iran J Radiol, 2012, 9(2): 63-66.
  • 3Stacul F, Thomsen HS. Nonionic monomers and dimers [J]. Eur Radiol, 1996, 6(5): 756-761.
  • 4Yaniv G, Portnoy O, Simon D, et al. Revised protocol for whole-body CT for multi-trauma patients applying triphasic injection followed by a single-pass scan on a 64-MDCT [J]. Clin Radiol, 2013, 68(7): 668-675.
  • 5Aertsen M, Termote B, Souverijns G, et aL The critical role of CT angiography in the detection and therapy of lower gastro-intestinal bleeding [J]. JBR-BTR, 2013, 96(2): 78-80.
  • 6Verburg FA, Apitzsch J, Lensing C, et al. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: influence on quantitative and clinical assessment in combined PET/CT [J]. Eur J Radiol, 2013, 82(12): 2348-2352.
  • 7Mrowietz C, Franke RP, Jung F. Influence of different radiographic contrast media on the echinocyte formation of human erythrocytes [J]. Clin Hemorheol Microcirc, 2012, 50(1-2): 35-47.
  • 8Seeliger E, Cantow K, Arakelyan K, et al. Low-dose nitrite alleviates early effects of an X-ray contrast medium on renal hemodynamics and oxygenation in rats [J]. Invest Radiol, 2014, 49(2): 70-77.
  • 9Sahani DV, Soulez G, Chen KM, et al. A comparison of the efficacy and safety of iopamidol-370 and iodixanol-320 in patients undergoing multidetector-row computed tomography [J]. Invest Radiol, 2007, 42(12): 856-861.
  • 10吕树铮.对比剂:让人类健康前景“清晰”显现[N].中国医学论坛报,2013-07-11(10).

二级参考文献17

  • 1Weissleder R.Molecular imaging:exploring the next frontier.Radiology,1999,212:609-614.
  • 2Lee SH,Bae KH,Kim SH,et al.Amine-functionalized gold nanoparticles as non-cytotoxic and efficient intracellular siRNA delivery carriers.Int J Pharm,2008,364:94-101.
  • 3Li P,Li D,Zhang L,et al.Cationic lipid bilayer coated gold nanoparticles-mediated transfection of mammalian cells.Biomaterials,2008,29:3617-3624.
  • 4Ghosh P,Han G,De M,et al.Gold nanoparticles in delivery applications.Adv Drug Deliv Rev,2008,60:1307-1315.
  • 5Alric C,Taleb J,Le Due G,et al.Gadolinium chelate coated gold nanoparticles as contrast agents for both X-ray computed tomography and magnetic resonance imaging.J Am Chem Soc,2008,130:5908-5915.
  • 6Xu C,Tung GA,Sun S.Size and concentration effect of gold nanoparticles on X-ray attenuation as measured on computed tomography.Chem Mater,2008,20:4167-4169.
  • 7Shi X,Wang S,Sun H,et al.Improved biocompatibility of surface functionalized dendrimer-entrapped gold nanoparticles.Soft Matter,2007,3:71-74.
  • 8Shi X,Wang S,Meshinchi S,et al.Dendrimer-entrapped gold nanoparticles as a platform for cancer-cell targeting and imaging.Small,2007,3:1245-1252.
  • 9Peer D,Karp JM,Hong S,et al.Nanocarriers as an emerging platform for cancer therapy.Nat Nanotechnol,2007,2:751-760.
  • 10Geso M.Gold nanoparticles:a new X-ray contrast agent.Br J Radiol,2007,80:64-65.

共引文献1

同被引文献36

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部