摘要 为满足卷烟焦油释放量逐年降低对于低焦油释放量监测卷烟的研制需求,在YC/T189-2004的基础上,通过烟叶原料选择、过程控制优化,研究制作了低焦油释放量监测卷烟样品,并对该样品进行均匀性检验和定值。结果表明:①F检验显示条间不存在显著性差异,均匀性良好;②16家实验室对该样品焦油释放量的联合定值结果为7.65 mg/cig,重复性标准偏差为0.17mg/cig,再现性标准偏差为0.41 mg/cig。 Low-tar monitoring cigarette samples were prepared based on YC/T 189-2004 to meet the demand of quality control of low tar cigarettes in tobacco industry. Homogeneity and values were also measured. Results showed that: 1)F test showed no significant differences existed between cartons. 2) mean tar delivery of 16 collaborating laboratory was 7.65 mg/cig, with repeatability standard deviation and reproducibility standard deviation as 0.17 mg/cig and 0.41 mg /cig, respectively.
出处 《中国烟草学报》 EI CAS CSCD 北大核心 2014年第3期30-35,共6页 Acta Tabacaria Sinica
基金 国家烟草专卖局标准制修订项目"焦油量低于8毫克的监测卷烟的研究与制作"(合同号:2011B055)
关键词 焦油 监测卷烟 均匀性 吸烟机 常规分析 tar delivery monitor test piece homogeneity smoking machine routine analysis
  • 相关文献

参考文献15

  • 1全国烟草标准化技术委员会.YC/T189-2004烟草及烟草制品监测卷烟的要求和应用[S].北京:中国标准出版社,2005.
  • 2全国烟草标准化技术委员会.GB/T16450-2004常用分析用吸烟机定义和标准条件[S].北京:中国标准出版社.2005.
  • 3全国烟草标准化技术委员会.GB/T19609-2004卷烟用常规分析用吸烟机测定总粒相物和焦油[s].北京:中国标准出版社,2006.
  • 4全国烟草标准化技术委员会.GB/T23355-2009卷烟总粒相物中烟碱的测定气相色谱法[S].北京:中国标准出版社,2009.
  • 5全国烟草标准化技术委员会.GB/T23356-2009卷烟烟气气相中一氧化碳的测定非散射红外线法[S].北京:中国标准出版社,2009.
  • 6ISO 16055--2003 Tobacco and tobacco products--Monitor test piece--Requirements and use[S].
  • 7JJG1006-1994.一级标准物质技术规范[S].[S].,..
  • 8全国统计方法与应用标准化技术委员会.GB/T6379.2-2004测量方法与结果的准确度(正确度与精密度)第2部分:确定标准测量方法重复性与再现性的基本方法[S].北京:中国标准出版社,2004.
  • 9刘峘.烟草加工中固体物料混合的探讨[J].烟草科技,2002,35(7):6-9. 被引量:21
  • 10温若愚,席年生,张大波,赵维一,郑建,刘德安,龙君.不同混丝模式对烟丝掺配效果的影响[J].烟草科技,2008,41(9):13-16. 被引量:13