期刊文献+

离网型斯特林异步发电技术研究

Research on off-grid stirling engine power system based on squirrel-cage induction generator
下载PDF
导出
摘要 根据斯特林发动机和异步发电机的特点,采用串联结构的异步发电模式,通过三相PWM全桥变换器解决了离网型斯特林发电系统的起动和发电问题,实现起动/发电双功能,使功率双向流动。系统电机控制采用带端电压补偿的V/f控制策略,对蓄电池采用DC-DC桥臂进行独立控制,稳态时保持蓄电池缓慢充电,在负载突变时,蓄电池相应放出或吸收能量,缓冲发动机的能量调节过程。仿真和实际示范应用证明了本系统的正确性和可行性。 According to the characteristics of stirling engine and induction generator, a three-phase full-bridge converter was used to solve the generation problem of off-grid stirling power generation system by using cascade structure mode, which realizes power two-way flowing function. The generator control is V/f control with voltage compensation. The battery control is DC-DC control, which makes it charge slowly at the state of stable, and discharge or absorb power when the load changes. The simulation and experiment both verify the feasibility.
出处 《电子设计工程》 2014年第13期161-164,共4页 Electronic Design Engineering
基金 国家海洋局可再生能源专项资金(GHME2011GC01) 上海市科技攻关项目(12dz1201200) 上海市节能减排项目(11dz1202700) 上海市科委创新行动计划项目(13DZ2250100)
关键词 离网型 斯特林发动机 异步发电机 V f控制 off-grid stirling engine induction generator V/f control
  • 相关文献

参考文献6

二级参考文献50

  • 1顾伟峰,马伟明,王东,肖飞,张波涛.12/3相双绕组异步发电机自激起励时谐波谐振问题研究[J].中国电机工程学报,2004,24(6):167-171. 被引量:22
  • 2[1]Malik E. Elbaluk. Potential starter/generator technologies for future aerospace application. IEEE AES System Magazine. 1997 (5) :1764~1769
  • 3[2]Muliadi E, Lipo T A. Series compensated PWM inverter with battery supplied to an isolated induction generator.IEEE Trans. on Industry Applications, 1994, 30 (4):1073~1082
  • 4[3]Marra E G, Pomilio J A. Self-excited induction generator controlled by a VS-PWM bidirectional converter for rural applications. IEEE Trans. on Industry Application, 1999,35 (4) :877~883
  • 5[4]Marra E G, Pornillio J A. Induction generator based system providing regulated with constant frequency. APEC' 99:410 ~415
  • 6[5]Singh Shilpaker. Analysis of solid state voltage regulator for a self-excited induction generator. Proc-Gener. Transm.Distrib. 1998, 145 (6) :647~655
  • 7[6]Lyra R O C, Silva S R, Cortizo P C. Direct and indirect flux control of an isolated induction generator. Proceedings of the International Conference on Power Electronics andDrive Systems. IEEE, Piscataway, NJ, USA: 1995 (1) :140~145.
  • 8[7]Liao Y W, Levi E. Modelling and simulation of a standalone induction generator with rotor flux oriented control.Electric Power Systems Research. 1998, 46 (2) : 141~152.
  • 9[8]Margato E, Santana J. Induction generator excited by current source inverter used as a D. C. power supply-modeling and behavior. IEEE International Symposium on Industrial Electronics. 1996 (2) :814~819.
  • 10[9]Donlon J, Motto E, Majumdar G, et al. A new converter/inverter system for wind power generation utilizing a new 600 Amp. 1200 Volt intelligent IGBT power module.Proc . IEEE Ind. Appl . Soc. Annual Meeting IAS ,Denver, 1994:1031~1042

共引文献39