Sirius系统与Lenstar 900测量眼前节参数的比较研究 被引量:3

Comparison of anterior segment parameters with Lenstar 900 and Sirius system
下载PDF
导出
摘要 目的:比较两种非接触眼生物测量仪Lenstar 900( LS900)和Sirius眼前节分析系统测量眼前节有关参数的异同。 方法:对近视患者54例87眼分别采用LS900及Sirius系统测量角膜中央厚度( central corneal thickness, CCT)、前房深度(aqueous depth, ACD)、角膜平K(flat keratometry, FK)、角膜陡 K(steep keratometry,SK)、白到白(white to white, WTW)。采用配对 t 检验、Pearson 相关和 Bland-Altman图分析和评估。 结果:Sirius系统检测的CCT和ACD大于LS900,而FK、SK和 WTW 小于 LS900,差值的均值分别为-6.11±6.32μm;-0.09±0.07 mm;0.18±0.25 D;0.21±0.36 D 和0.25±0.39mm,差异有统计学意义(P〈0.01)。 Pearson相关性分析两种检测结果均显著相关( P〈0.01)。 Bland-Altman 一致性比较:95%一致性界限分别为6.26~18.49μm,0.04~0.22mm,0.68~0.32D,0.92~0.50D和1.00~0.5mm。 结论:LS900和Sirius系统对眼前节参数的检测具有良好的相关性和一致性,但也存在一定差异。这可能与Lenstar和Sirius测量方式并不一致有关,因此还有待进一步研究。 AIM: To compare the anterior segment measurements derived from optical low coherence reflectometer ( Lenstar LS900 ) and combined Scheimpflug Placido disk topographer ( Sirius). METHODS: In this study, we enrolled healthy myopic subjects 54 (87 eyes). The central corneal thickness (CCT, anterior chamber depth (ACD), flat keratometry (FK readings , steep keratometry (SK) readings and white to white (WTW were measured by LS900 and Sirius. Evaluation and analysis were performed using paired t tests, the Pearson correlation, and Bland-Altman analyses. RESULTS: The CCT and ACD measurements were significantly lower whereas FK, SK and WTW measurements were higher with LS900 ( P〈0.001 ). Mean differences were -6.11 ±6.32μ m,-0.09±0.07mm, 0.18± 0.25D, 0. 21 ± 0.36D and 0.25 ± 0. 39mm with statistical significant ( P〈0.01 ). Pearson correlation analysis showed high correlation between the 2 devices for all measurements ( P〈 0. 001 ). On Bland- Altman analysis, 95% limits of agreement for all measurements were 6.26 to -18.49μm; 0.04 to 0.22mm; 0.68 to 0.32D; 0.92 to 0.50D and 1.00 to 0.5mm. CONCLUSION: Anterior segment parameters evaluated with LS900 and Sirius systemare correlated well and achieve good agreement. However, there are significantly statistical differences which may be caused by the different measurement modes, so they may not be interchangeable use under certain clinical circumstances.
出处 《国际眼科杂志》 CAS 2014年第7期1250-1252,共3页 International Eye Science
关键词 Sirius系统 LENSTAR 900 眼前节参数 一致性 Sirius system Lenstar 900 anteriorsegment parameters agreement
  • 相关文献

参考文献7

  • 1Wang M. Corneal topography in the wavefront era. A guide for clinical application. Thorofare: SLACK, Inc. 2008:13.
  • 2Javaloy J, Vidal MT, Villada JR,et al. Comparison of four corneal pachymetry techniques in corneal refractive surgery. J Refract Surg 2004; 20(1):29-34.
  • 3Barkana Y, Gerber Y, Elbaz U, et al. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg 2005; 31(9):1729-1735.
  • 4Zhao J, Chen Z, Zhou Z,et al. Evaluation of the repeatability of the Lenstar and comparison with two other non-contact biometric devices in myopes. J Clin Exp Optom 2013; 96(1):92-99.
  • 5Ho T, Cheng AC, Rao SK,et al. Central corneal thickness measurements using Orbscan II, Visante, ultrasound and Pentacam pachymetry after laser in situ keratomileusis for myopia. J Cataract Refract Surg 2007; 33(7):1177-1182.
  • 6孙成淑,黄永志,张小兰,王琳.Lenstar LS900与SIRIUS眼前节分析系统对角膜中央厚度测量结果的比较[J].国际眼科杂志,2012,12(9):1711-1712. 被引量:4
  • 7Aristodemou P, Cartwright NE, Sparrow JM, et al. Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg 2011; 37(1):63-71.

二级参考文献6

共引文献3

同被引文献13

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部