期刊文献+

傅里叶变换红外成像光谱仪非均匀性在线定标与校正研究 被引量:5

Study on Nonuniformity Online Calibration and Correction of Fourier Transform Infrared Imaging Spectrometer
下载PDF
导出
摘要 由于傅里叶变换红外成像光谱仪结构的特殊性,其非均匀性在线定标与校正在工程上一直没有得到有效解决。首先对IRFPA非均匀性校正的原理与算法进行了简要阐述,在此基础上,通过对时间调制型、空间调制型及时间空间联合调制型傅里叶变换红外成像光谱仪原理结构的深入分析,针对这三种制式的光谱仪,分别研究出了相应的非均匀性在线定标与校正的方法,为星载傅里叶变换红外成像光谱仪非均匀性的在轨定标奠定了良好的技术基础。 Due to the particular structure of Fourier transform infrared imaging spectrometer, its nonuniformity online calibration and correction is always a technical problem that has not been solved in engineering. Based on brief review to the principle and algorithm of nonuniformity correction of IRFPA, through in-depth analysis of principle and structure of time modulation, space modulation type and time and space combined modulation type Fourier transform infrared imaging spectrometer, it is given that online method for non-uniformity calibration and correction of three types of Fourier transform infrared imaging spectrometer, which should establish a good technical foundation to on-orbit nonuniformity calibration and correction for Fourier transform infrared imaging spectrometer on satellite.
出处 《红外技术》 CSCD 北大核心 2014年第7期567-572,共6页 Infrared Technology
基金 国家自然科学基金 编号:61265006 广西自然科学基金 编号:2013GXNSFAA019325 广西科学研究与技术开发项目 编号:桂科攻1348020-10 广西信息科学实验中心项目 编号:20130106
关键词 傅里叶变换 红外成像光谱仪 非均匀性 在线定标 在线校正 Fourier transform infrared imaging spectrometer nonuniformity online calibration online correction
  • 相关文献

参考文献5

二级参考文献58

共引文献130

同被引文献35

  • 1连晨舟,吕子安,季春生,李定凯,徐旭常.一种标定新方法在FTIR定量分析中的应用[J].光谱学与光谱分析,2004,24(11):1323-1326. 被引量:4
  • 2魏儒义,雷俊锋,杨琨,尹邦胜,曾立波.傅里叶变换红外光谱仪中立方反射镜特性分析[J].光学仪器,2007,29(3):69-75. 被引量:6
  • 3梁铨廷.物理光学[M].北京:机械工业出版社,1980.
  • 4Su Lijuan, Yuan Yan, Bin Xiangli. Spectrum reconstructionmethod for airborne temporally- spatial 1 y modulated Fouriertransform imaging spectrometers [J]. IEEE Transactions onGeoscience and Remote Sensing, 2014, 52(6): 3720-3728.
  • 5Rossi Alessandro, Diani Marco, Corsini Giovanni. Bilateralfilter-based adaptive nonuniformity correction for infraredfocal-plane array systems [J]. Optical Engineering,2010,49(5): 057003.
  • 6Zhang Peng, Zhang Zhihui,Han Shunli. The research ofapodization method of Fourier transform spectrometer [C]//International Symposium on Photoelectronic Detection andImaging 2013: Imaging Spectrometer Technologies andApplications, Proceedings of SPIE, 2013, 8910.
  • 7Takada Kazumasa, Aoyagi Hirotaka, Okamoto Katsunari.Correction for phase-shift deviation in a complex Fourier-transform integrated-optic spatial heterodyne spectrometerwith an active phase-shift scheme [J]. Optics Letters, 2011,36(7): 1044-1046.
  • 8Miles A J, Wien F, Lees J G. Calibration and standardisationof synchrotron radiation and conventional circular dichroismspectrometers. Part 2: Factors affecting magnitude andwavelength [J]. Spectroscopy -AN International Journal,2005, 19(1): 43-51.
  • 9J Connes. Spectroscopic studies using Fourier transfor- mations[J]. Rev. Opt., 1961, 40(23).- 45-49.
  • 10Joseph B C, Fuller Jr. Retroreflector concepts: cor- ner-cube compared to catseye[C]. SPIE, 1987, 818: 1117-1123.