摘要 采用聚合变色体系,以类丁二炔单体PCDA为变色染料,制备了一种用于辐照剂量预警的自显色个人剂量计。对基体材料、稀释剂种类、变色染料、溶解温度、成膜厚度以及膜制备工艺进行了研究,建立了自显色个人剂量计制备方法。剂量计接受0.1-2.5 Gy辐照后,颜色从白色变为蓝色,在681.5 nm处测得剂量响应曲线线性相关系数为0.9998,照后两周内稳定性良好,可作为预警式个人剂量计使用。 A self-indicating radiation personal dosimeter was investigated using radiation sensitive material diacetylene monomer PCDA ,which was a component of the polymeri-zation system .The substrate material ,solvent ,sensitive material ,solution tempera-ture ,thickness of film and the preparation method were studied .The dosimeter colour changes from w hite to blue w hen exposed 0.1-2.5 Gy ,and the linearly dependent coeffi-cient of the exposure response is 0.999 8 ,the stability of absorbency in two weeks after exposure is testified well . It can be used as self-indicating radiation alert personal dosimeter .
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2014年第7期1321-1324,共4页 Atomic Energy Science and Technology
关键词 个人剂量计 自显色 类丁二炔单体 personal dosimeter self-indicating diacetylene monomer
  • 相关文献

参考文献5

  • 1TSANG C, BUTSON M J, PETER K N Y. Re- flection spectrometry analysis of irradiated GAF- CHROMIC XR type R radiochromic films[J]. Appl Radiat Isot, 2005, 63: 127-129.
  • 2TSANG C, BUTSON M J, PETER K N Y. X- ray energy dependence of the dose response of SIRAD radiation dosimeters[J]. Appl Radiat Isot, 2007, 65: 814-817.
  • 3BUTSON M J, TSANG C, PETER K N Y. Visible absorption spectra of radiation exposed SIRAD dosimeters [J]. Phys Med Biol, 2006, 51: N417-N421.
  • 4PATEL G N. A general purpose, high accuracy dosimeter reader: US, 039623[P]. 2006-01-31.
  • 5PATEL G N. Method of making smart cards with an encapsulant: US, 002574[P]. 2007-08-30.