期刊文献+

Simultaneous Determination of Trace Lead and Chromium in Water Using Laser-Induced Breakdown Spectroscopy and Paper Substrate 被引量:1

Simultaneous Determination of Trace Lead and Chromium in Water Using Laser-Induced Breakdown Spectroscopy and Paper Substrate
下载PDF
导出
摘要 Toxic metals such as lead and chromium in aqueous solutions have been analyzed simultaneously by laser-induced breakdown spectroscopy(LIBS), in which the ordinary printing paper is used as a liquid absorber which was immerged into Pb(NO3)2and Cr(NO3)3aqueous solution to enrich the heavy metals. This method overcomes the drawbacks of splashing and low sensitivity in ordinary LIBS analysis of water, in which a laser beam is directly focused on a liquid surface. A good signal intensity and reproducibility has been demonstrated. The Pb 405.78 nm and Cr 427.48 nm spectral lines are used as the analytical lines. The variation of line intensity with immersion time was investigated. The calibration curve for quantitative measurement of Pb and Cr in water was established, and the detection limits are 0.033 mg/L and 0.026 mg/L respectively,which is about 2-3 orders of magnitude better than that in the ordinary LIBS analysis of heavy metal in solution. Toxic metals such as lead and chromium in aqueous solutions have been analyzed simultaneously by laser-induced breakdown spectroscopy(LIBS), in which the ordinary printing paper is used as a liquid absorber which was immerged into Pb(NO3)2and Cr(NO3)3aqueous solution to enrich the heavy metals. This method overcomes the drawbacks of splashing and low sensitivity in ordinary LIBS analysis of water, in which a laser beam is directly focused on a liquid surface. A good signal intensity and reproducibility has been demonstrated. The Pb 405.78 nm and Cr 427.48 nm spectral lines are used as the analytical lines. The variation of line intensity with immersion time was investigated. The calibration curve for quantitative measurement of Pb and Cr in water was established, and the detection limits are 0.033 mg/L and 0.026 mg/L respectively,which is about 2-3 orders of magnitude better than that in the ordinary LIBS analysis of heavy metal in solution.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第7期683-687,共5页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China(No.61178034) Key Research Project of University of Zhejiang Province,China(No.ZD2009006) the Program for Innovative Research Team,Zhejiang Normal University,China
关键词 LIBS SOLUTION quantitative analysis paper substrate LIBS solution quantitative analysis paper substrate
  • 相关文献

参考文献35

  • 1Tong S, von Schirnding Y E, Prapamontol T. 2000 Bull World Health Organ, 78:1068.
  • 2Horiguchi H, Teranishi H, Niiya K, et al. 1994, Arch. Toxicol., 68:632.
  • 3Antonio M T, Leret M L. 2000, Life Sci., 67:635.
  • 4Lidsky T I, Schneider J S. 2003, Brain, 126:5.
  • 5Nuyts G D, Elseviers M M, and De Broe M E. 1989, Toxicol. Lett., 46:31.
  • 6Il'yasova D, Schwartz G G. 2005, Toxicol. Appl. Phar- macol., 207:179.
  • 7Al-Saleh I, Coskun S, Mashhour A, et al. 2008, Int. J. Hyg. Environ. Health, 211:560.
  • 8Edwards M, Triantafyllidou S, Best D. 2009, Environ. Sci. Technol., 43:1618.
  • 9Cabrera C, Lopez M C, Gallego C, et al. 1995, Sci. Total Environ., 159:17.
  • 10Zhou W, Li K, Shen Q, et al. 2010, Opt. Express., 18: 2573.