微污染原水O_3—BAC池的失效评价 被引量:2

Failure evaluation of the O_3-BAC to treat the micro-polluted raw water
下载PDF
导出
摘要 提出了出水满足水质标准兼顾对目标污染物抗冲击负荷能力的活性炭失效诊断方法。中试结果表明,S 市 M 水厂运行9年后的1#炭对 CODMn和 DOC 的平均去除率分别为22%和31%;对苯酚、2 MIB 以及三氯乙醛前体物等目标污染物的去除能力分别为76.9%~93.1%、30.0%~44.1%及28.0%。相比2#新炭的运行效果而言,1#炭对有机物仍具有去除效果且出水能够满足水质标准,对目标污染物也具备一定的抗冲击负荷能力。 This paper brought forward the evaluation method for the inability of activated carbon to treat the water and to take the shock load of pollutants.The pilot study showed that the average removal rates of CODMn and DOC of 1 # activated carbon in M Water Treatment Plant of S City were 2 2 .0% and 3 1%,respectively;its removal rates on phenol,2-MIB and the precursor of chloral were 7 6 .9%~93.1%、30.0%~44.1% and 28.0%,respectively.Compared with the operation results of 2# new car-bon,the removal ability of 1# activated carbon on organic matter contend could meet the standards of effluent and 1 # activated carbon could also sustain the shock load to some degree.
出处 《给水排水》 CSCD 北大核心 2014年第8期9-13,共5页 Water & Wastewater Engineering
基金 国家水体污染控制与治理科技重大专项(2009ZX07423-003)
关键词 活性炭 失效 DOC 苯酚 2-MIB 三氯乙醛 前体物 Activated carbon Failure DOC Phenol 2-MIB Chloral Precursor
  • 相关文献

参考文献9

二级参考文献49

  • 1乔铁军,安娜,尤作亮,张金松.梅林水厂臭氧/生物活性炭工艺的运行效果[J].中国给水排水,2006,22(13):10-13. 被引量:48
  • 2张金松.臭氧-生物生炭工艺过程研究.哈尔滨建筑大学博士论文[M].,1995..
  • 3[1]Patrick Niquette.Shutdown of BAC flters:effects on water quality[J].J AWWA,1998,(12):53-61.
  • 4张金松,李伟光,马放,赫俊国,袁纯英.臭氧接触装置的传质与吸收试验研究[J].哈尔滨建筑大学学报,1997,30(2):75-79. 被引量:6
  • 5Committee Report An Assessment of Microbial Activity on GAC. Journal AWWA 1981,73:447-454.
  • 6Yin, W, C. and Weber E. J. Jr Bio-physicochemical Adsorption Model Systems for Wastewater Treatment, Journal WPCF, 1979, 51: 2661-2677.
  • 7Ferhan C. And ozgur Aktas Powdered Activated carbon-assisted Biotreatment of a Chemical Synthesis Wastewater. Journal Chem Technol Biatechnol, 2001,76 : 1249-1259.
  • 8G. M. Walker, L. R. Weatherley Biological Activated Carbon treatment of industrial wastewater in stirred tank reactor. Chemical Engineering Journal, 1999,75 : 20-206.
  • 9G.T. Seo and Se Evaluation of Refractory Organic Removal in Combined Biological Powdered Activated Carbon-microfiltratioa for Advanced Wastewater Treatment, Water Science and Technology, 2001,43(11) :67-74.
  • 10Metcalf&Eddy Inc.Wastewater Engineering Treatment and Reuse(Fourth edition)Ⅱ[M].北京:清华大学出版社,2003..

共引文献101

同被引文献42

引证文献2

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部