摘要 目的用比色法测定伊班膦酸钠注射液中的游离磷酸盐。方法采用乙酸丁酯萃取注射液中的磷钼酸铵,再加入氯化亚锡-抗坏血酸溶液作为还原剂,生成稳定的蓝色化合物,测定波长为720 nm。结果方法的线性范围为1.0~10.0μg·mL-1,回收率为96.5%,RSD=1.17%(n=9)。结论所用方法简便、快速准确、重复性好,可用于测定伊班膦酸钠注射液中的游离磷酸盐。 OBJECTIVE To establish a clorimetric method for the determination of free phosphate in Ibandronate sodium injection. METHODS Butyl acetate extraction was used in aqueous solution of ammonium molybdate, and then stannous chloride - ascorbic acid solution was added as reducing agent, and a stable blue chemical compound was gained. The detected wavelength was 720 nm. RESULTS The calibration curve of free phosphate was linear beteen 1.0 - 10.0 μg· mL^- 1 , and the average recovery were 96.5 % , RSD = 1.17% (n = 9). CONCLUSION The method is simple, rapid, accurate and reproducible,and can be used for the determination of free phosphate in this product.
出处 《华西药学杂志》 CAS CSCD 北大核心 2014年第4期419-420,共2页 West China Journal of Pharmaceutical Sciences
关键词 比色法 伊班膦酸钠 磷酸盐 含量测定 Colorimetric method Ibandronate sodium Phosphate Assay
  • 相关文献

参考文献2

二级参考文献7

  • 1赫立恩,张嫡群,房桂珍,王云志.荧光淬灭法测定伊班膦酸钠注射液含量[J].药物分析杂志,2005,25(2):220-222. 被引量:4
  • 2Kline WF, Maluszewski BK. Improved determination of the bisphosphonate alendronate in human plasma and urine by automated precolumn derivetization and high perfomance liquid chromatography with fluorescence and electrochemical detection. J Chromatogr B, 1992,583(2) :183.
  • 3Sparidans RW, Hartigh JD, Beijnen JB,et al. Determination of pamidronate in urine by ion- pair liquid chromatography after derivatization with 1 - naphthiocyanate fluorescence and electrochemical detection. J Chromatogr B,1997,696( 1 ) :137.
  • 4Sparidans RW, Hartigh JD, Vermeij P, et al. High perfomance ion exchange chromatography with in - line complaxation of bisphosphonate and their quality control in pharmaceutical, preparations. J Pharm Biomed Anal, 1995,13(12): 1545.
  • 5Meek SE, Pietrzyk DJ. Liquid chromatographic separation of phosphorus oxo acid and other anions with post - column indiract fluoreacece detection by aluminium- morin..Anal Chem, 1988,60(14) :1397.
  • 6谢永洪,张新申,杨坪,钱蜀,张丹.分光光度法测定磷酸盐的研究进展[J].皮革科学与工程,2009,19(2):35-41. 被引量:23
  • 7周杏琴,胡名扬,杨敏,王博诚.伊班膦酸钠片含量分析方法的研究[J].药物分析杂志,2001,21(6):396-398. 被引量:1

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部