摘要 以微弧氧化后的钛合金为基体,采用水热电化学法制备了 HA/TiO 2涂层.利用 SEM、XRD 对涂层的表面形貌、物相组成进行了表征分析,通过 pH 微探针原位探测电极/电解液界面 pH 值的变化,研究了pH 值和缓冲剂对水热电化学沉积 HA/TiO 2涂层的影响.研究结果表明,微弧氧化膜有利于水热电化学沉积 HA,得到的 HA 晶体分布均匀、致密.当电解液pH 值在2~8时,pH 值升高有利于提高水热电化学沉积 HA 的结晶度,并促使 HA 沿(002)晶面生长.在水热电化学沉积 HA 过程中,电极表面的 pH 值随沉积时间的增加先升高后逐渐降低;而溶液中的 pH值随沉积时间的增加逐渐降低.pH 值和缓冲剂对涂层 HA 晶体形貌有明显影响,加入缓冲剂后得到的HA 晶体端面呈六边形棒状结构,晶体表面光滑、结晶完整. Using titanium alloy after micro-arc oxidation as substrate,HA/TiO 2 coatings were prepared by hy-drothermal-electrochemical method.The morphologies and phase compositions of coatings were characterized by means of SEM and XRD,and the variation of pH value of electrode/electrolyte was measured by means of pH microprobe;in this way,the influences of pH value and slow granule on HA/TiO 2 coatings deposited by hydro-thermal-electrochemical method were investigated.The results show that micro-arc oxidation coatings contrib-ute to HA deposited by hydrothermal-electrochemical method and HA crystals are well-distributed and densified in the coatings.When the pH value was within the range of 2 to 8,the increasing of the pH value contributes to HA crystals with high crystallinity and the growth of HA along the crystallographic plane (002).During the process of depositing HA by hydrothermal-electrochemical method ,pH value on the surface of electrode increa-ses at first and then decreases with the deposition time,while pH value of electrolyte decreases with the deposi-tion time.pH value and slow granule have obvious influences on the morphologies of HA crystals.HA crystals prepared in the electrolyte containing slow granule are rods in shape,the edge face of rod was a defined flat hex-agon and the surface of the crystal was smooth,and HA crystals are well-crystallized.
出处 《功能材料》 EI CAS CSCD 北大核心 2014年第7期7094-7098,共5页 Journal of Functional Materials
基金 国家自然科学基金资助项目(51201107) 上海市自然科学基金资助项目(09ZR1422100) 上海市科学技术委员会重点科技攻关资助项目(11441900501) 上海市教委科研创新一般资助项目(10YZ94)
关键词 微弧氧化膜 水热电化学法 羟基磷灰石 pH 缓冲剂 micro-arc oxidation coatings hydrothermal-electrochemical method hydroxyapatite pH value slow gran-ule
  • 相关文献

参考文献21

  • 1孙敬,崔振铎,朱胜利,杨贤金.生物医用植入钛及钛合金的力学性能研究及进展[J].金属热处理,2005,30(9):59-62. 被引量:16
  • 2DeGrootK,GeesinkR,KeinCPAT,etal.[J].JBiomedMaterRes,1987,21:1375-1382.
  • 3ZhaoB,DuRG,LinCJ,etal.Newdevelopmentsinthepreparationofhydroxyapatitebioceramic materials [J].JournalofFunctionalMaterials,2003,34(2):126-132.
  • 4梁芳慧,周廉.钛和钛合金生物活化研究现状[J].稀有金属材料与工程,2003,32(4):241-245. 被引量:27
  • 5ChanCAN,CheungK H,OngJ,etal.IsHAcoatingbeGnefical[J].ChineseJournalofOralImplantology,1998,3(1):45-48.
  • 6KajiyoshiK,IshizawaN,Yoshimura M.Preparationoftetrageonalbariumtitanatethinfilm ontitanium metalsubstratebyhydrothermalmethod[J].Am Ceram Soc,1991,74(2):369-374.
  • 7BanS,MarunoS.EffectoftemperatureonelectrochemiGcaldepositionofcalciumphosphatecoatingsinasimulaGtedbodyfluid[J].Biomaterials,1995,16:977-981.
  • 8BanS,MarunoS,HaradaA,etal.Effectoftemperatureonmorphologyofcalcium phosphatesdepositedbyelecGtrochemicalmethod[J].DentMaterJ,1996,15:31-38.
  • 9BanS,MarunoS.MorphologyandmicrostructureofelecGtroGchemicallydepositedcalciumphosphatesinamodifiedsimulatedbodyfluid[J].Biomaterials ,1998,19:1245-1253.
  • 10LiuF,LiZY,ZhouKC,etal.PreparationofHAcoatGinginlowCa/Pratiosolutionbyelectrodeposition[J].JCentSouthunivTechnol,2002,33(1):66-69.

二级参考文献43

  • 1林昌健,骆静利,孙海燕,杜荣归.扫描复合微pH电极原位测量局部腐蚀体系pH分布图象[J].电化学,1996,2(4):372-377. 被引量:10
  • 2鲍利索娃EA 陈石卿(译).钛合金金相学[M].北京:国防工业出版社,1986..
  • 3Yu Yaoting(俞耀庭) Zhang Xingdong(张兴栋).Biomedical Materials(生物医用材料)[M].Tianjin:Tianjin University Press,2000.131.
  • 4Fu Tao(付涛) Huang Ping(黄平) Han Yong(憨勇) Xu Kewei(徐可为).Rare Metal Materials and Engineering(稀有金属材料与工程),2000,29(3):168-168.
  • 5Zhang Yumei(张玉梅) et al.Rare Metal Materials and Engineering(稀有金属材料与工程),1999,28(2):125-125.
  • 6Yoshimitu Okazaki,Emiko Gotoh.Comparison of metal release from various metallic biomaterials in vitro[J].Biomaterisls,2005,26:11-21.
  • 7Yoshimitu Okazaki,Emiko Nishimura,Hiroshi Nakada.Surface analyses of Ti-15Zr-4Nb-4Ta alloy after implantation in rat tibia[J].Biomaterials,2001,22:599-607.
  • 8Yoshimitu Okazaki.Effect of Alloying Elements on Mechanical Properties of Titanium Alloys for Medical Implants[J].Materials Transactions,JIM,1993,34(12):1217-1222.
  • 9Yoshimitsu Okazaki,Yoshimasa Ito and Testsuya Tateishi.Effects of Heat Treatment Mechanical Properties and Corrosion Fatigue Strength in Physiological Saline Solution of New Titanium Alloys for Medical Implants[J].Materials Transactions,JIM,1996,37(4):843-849.
  • 10Ronald C Geveau.Nickel-free austenitic steel resists corrosion in the body[J].Advanced Materials & Processes,2001,159(6):11.

共引文献44

同被引文献11

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部