期刊文献+

干细胞采集中静脉补钙时机与速度的探讨 被引量:4

下载PDF
导出
摘要 目的探讨外周血干细胞采集过程中静脉补钙的最佳时机及速度,为有效预防和纠正枸橼酸钠毒性反应提供依据。方法使用COBE Spectra血细胞分离机对162例健康供者进行干细胞采集295例。将每次采集随机分为两组,观察组156例,对照组139例,进行不同时机、不同速度的静脉补钙观察与分析。结果两组干细胞采集均成功,共发生20例低钙反应,发生率为6.78%;对照组18例,发生率为12.95%;观察组发生2例,发生率为1.28%。观察组低钙反应发生率明显低于对照组(P<0.01)。结论正确的静脉补钙时机及速度,有效降低了枸橼酸钠毒性引起的不良反应。
出处 《护士进修杂志》 2014年第15期1415-1416,共2页 Journal of Nurses Training
关键词 干细胞采集 枸橼酸钠毒性反应 补钙 Stem collection Sodium citrate tonicity Calcium supplements
  • 相关文献

参考文献4

二级参考文献41

  • 1Balint B, Ljubenov M, Stamatovic D, et al. Stem cell harvesting protocol research in autologous transplantation setting: large volume vs. conventional cytapheresis. Vojnosanit Pregl 2008;65(7):545-551.
  • 2Pusic I, DiPersio JF. The use of growth factors in hematopoietic stem cell transplantation. Curt Pharm Des. 2008; 14(20): 1950-1961.
  • 3Moog R. Mobilization and harvesting of peripheral blood stem cells. Curr Stem Cell Res Ther 2006; 1 (2): 189-201.
  • 4Moog R. Apheresis techniques for collection of peripheral blood progenitor cells. Transfus Apher Sci 2004;31 (3):207-220.
  • 5Burger SR, Fautsch SK, Stroncek DE et al. Concentration of citrate anticoagulant in peripheral blood progenitor cell collections. Transfusion 1996; 36(9): 798-801.
  • 6Kishimoto M, Ohto H, Shikama Y, et al. Treatment for the decline of ionized calcium levels during peripheral blood progenitor cell harvesting. Transfusion 2002; 42(10): 1340-1347.
  • 7Heuft HG, Dubiel M, Kingreen D, et al. Automated collection of peripheral blood stern cells with the COBE spectra for autotransplantation.Vox Sang 2000;79(2):94-99.
  • 8Buchta C, Macher M, Bieglmayer C, et al. Reduction of adverse citrate reactions during autologous large-volume PBPC apheresis by continuous infusion of calcium-gluconate. Transfusion 2003;43 ( 11 ): 1615-1621.
  • 9Gasova, Z, Marinov I, Vodvarkova S, et al. PBPC collection techniques: standard versus large volume leukapheresis (LVL) in donors and in patients. Transfus Apher Sci 2005; 32(2):167-176.
  • 10Hitzler WE, Wolf S, Runkel S, et al. Comparison of intermittent-and continuous-flow cell separators for the collection of autologous peripheral blood progenitor cells in patients with hematologic malignancies. Transfusion 2001; 41(12):1562-1566.