期刊文献+

小型分体式空气源热泵除霜能耗来源分析与计算

Analysis and calculation of defrosting energy source for small split air source heat pump
下载PDF
导出
摘要 针对分体式空气源热泵逆循环除霜的特点,对其除霜能量来源特性进行了分析,并对各部分能量的计算方法做了介绍,分析表明空气源热泵除霜时压缩机作功、室内侧换热器翅片管贮存的热量、翅片管与室内环境自然对流换热吸热等三部分为除霜能量的主要来源。 Based on the characteristic of reverse cycle defrosting for the split air source heat pump,the defrosting energy source characteristics are analyzed and introduce the method for calculating each part of the energy. The experiment shows that the compressor work,the indoor side heat exchanger fin-tube stored energy and the natural convection heat transfer between indoor environment and the fin-tube are the main sources of defrosting.
出处 《山西建筑》 2014年第23期169-170,共2页 Shanxi Architecture
基金 东北林业大学本科生创新性实验项目(项目编号:201210225137)
关键词 空气源热泵 除霜 能耗 计算 air source heat pump defrosting energy consumption calculation
  • 相关文献

参考文献4

  • 1N. Hoffenbecker, S. A. Klein, D. T. Reindl. Hot Gas Defrost Model Development and Validation, Int. J. of Refrigeration, 2005,28 (3) :605-615.
  • 2姬长发,黄东,袁秀玲.风冷热泵冷热水机组结霜与除霜性能的实验研究[J].西安交通大学学报,2005,39(5):480-484. 被引量:13
  • 3J. P. Holman. Heat Transfer. China Machine Press, 2005:321- 323.
  • 4吴业正,李红旗,张华.制冷压缩机[M].第2版.北京:机械工业出版社,2010:24-26.

二级参考文献5

  • 1Nutter D W, O'Neal D L, Payne W V. Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor[J]. ASHRAE Transaction, 1993,99(1):689-698.
  • 2O'Neal D L, Peterson K T, Anand N K.Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost[J]. Int J Refrig, 1991, 14(7):52-57.
  • 3Huelle Z R. The MSS line-a new approach to the hunting problem[J]. ASHRAE Journal, 1972, 14(8): 43-46.
  • 4黄东,袁秀玲,张波,张兴群.风机提前启动对风冷热泵冷热水机组除霜的影响[J].西安交通大学学报,2004,38(5):448-451. 被引量:7
  • 5黄东,袁秀玲,张波,陈蕴光.节流机构对风冷热泵逆循环除霜性能的影响[J].哈尔滨工业大学学报,2004,36(5):697-700. 被引量:5