摘要
用高效液相色谱法定量分析(S)-2-氨基丁酰胺盐酸盐的纯度。用Agilent 1100型高效液相色谱仪,色谱柱Xterra C18(5μm,4.6 mm×250 mm),流动相为20%乙腈-80%,缓冲液:1000 mL水+5.0 g庚烷磺酸钠;检测波长为210 nm,流量为0.7 mL·min-1,柱温30℃,对(S)-2-氨基丁酰胺盐酸盐纯度进行定量测定。相对标准偏差0.15%,标准回收率99.8%~100.2%,方法重复性好,定量准确度高。
Purity analysis of (S)-2-Aminobutyramide hydrochloride was established by high performance liquid chromatography with Agilent 1100, Xterra C18(5 μm, 4.6 mm×250 mm)column, mobile phase was acetonitrile-water, detection wavelength was 210 nm, flow rate was 0.7 mL·min-1, column temperature was 30℃. The method showed repeatability and relative standard deviation was 0.15%, and the standard recoveries were 99.8%-100.2%. These quantitative results showed high accuracy.
出处
《上海计量测试》
2014年第2期40-41,共2页
Shanghai Measurement and Testing
关键词
高效液相色谱法
(S
)-2-氨基丁酰胺盐酸盐
high performance liguid chromatograph
(S)-2-Aminob-utyramide hydrochloride
purity