期刊文献+

1000MW汽轮发电机转子绕组匝间短路故障 被引量:2

Analysis of the Inter-turn Short Circuit of 1 000 MW Turbo Generator Windings
下载PDF
导出
摘要 对某电厂1000MW汽轮发电机在运行过程中发现转子的轴振动异常为例进行了分析。在结合运行记录和大修试验检测的相关数据分析后,认为转子存在早期匝间短路隐患。就大型汽轮发电机转子绕组匝间故障诊断方法及存在的问题进行了研究。 The anomaly of roller vibration occurred on the windings of a 1 000 MW operating turbo generator was analyzed as an example. With the recording data of operation and large - scale repairing, it is believed that an incipient fault of early - stage inter - turn short circuit existing on the windings. The main methods and its problems during diagnosing inter - turn problems of large turbo generator rotor windings was studied and discussed ; it also provides related experience and reference for the studies of similar large turbo generator sets.
出处 《云南电力技术》 2014年第3期90-92,共3页 Yunnan Electric Power
基金 中央高校基本科研业务费专项基金(武汉大学201120702020013)
关键词 汽轮发电机 转子绕组 匝间短路 turbo generator rotor windings inter- turn short circuit
  • 相关文献

参考文献6

二级参考文献29

共引文献117

同被引文献10

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部