期刊文献+

强震动观测台站防雷措施探讨 被引量:3

Discussion on Lightning Protection Measures of Strong Earthquake Monitoring Stations
下载PDF
导出
摘要 雷电危害是影响地震台站稳定运行的重要因素之一,对台站进行雷电防护具有重要意义。分析雷电对地震台站的危害,结合强震动观测台站的建设要求与建设情况,介绍可行的防雷系统,并从台站选址建设、供电系统、接地系统、仪器防雷、通信防雷等方面对台站防雷措施进行探讨。 Lightning is one of the important factors affecting the stable operation of seismic stations, and it's significant to develop lightning protection for stations. This article analyzes the harm of lightning on seismic stations, and introduce one type of practical lightning protection system by combining the construction requirements and construction situation of strong earthquake monitoring stations, furthermore, it investigates the measures about lightning protection of seismic stations in terms of site selection and construction, power supply system, grounding system, equipments and communication, etc.
机构地区 广东省地震局
出处 《华南地震》 2014年第2期107-114,共8页 South China Journal of Seismology
基金 中国地震局地震行业科研专项(201208014)
关键词 雷电 台站 防雷措施 Lightning Seismic station Lightning protection measure
  • 相关文献

参考文献3

  • 1马明 吕伟涛 张义军 等.中国雷电活动特征分析.气象科技,2007,35:1-7.
  • 2中国地震局.2001.地震学与测震技术[M].北京:地震出版社.
  • 3王常余.接地技术220问[M].上海:上海科学技术出版社,2001.

共引文献33

同被引文献19

引证文献3

二级引证文献6