变容量家庭能源中心制冷兼制热水模式性能实验研究

Experimental Study on Space Cooling & Water Heating Mode of Domestic Energy System with Variable Capacity Compressor
下载PDF
导出
摘要 现有的多功能热泵机组的制冷兼制热水模式存在结构复杂、能量控制难以满足需求等问题,为此,提出基于数码涡旋压缩机的变容量家庭能源中心系统,并确定制冷兼制热水模式的机组性能系数计算方法。通过实验对比分析制冷兼制热水模式和单独制冷模式的性能,结果表明:与单独制冷模式相比,制冷兼制热水模式的制冷量有所衰减,但机组的总能量输出和性能系数分别提高了17.3%和36.8%。实验研究制冷兼制热水模式在水箱初始温度、不同压缩机负荷和不同环境温度下的动态特性和性能表现。通过分析该模式在各种工况下的性能变化规律,总结控制策略,可保证该模式的安全高效运行。 To solve the problems of complex structure and unsuitable capacity control of present multi-function heat pump system,domestic energy system is introduced. A new system performance indicator is chosen to describe the performance of space cooling&water heating mode. By comparison with space cooling only mode,this mode has been proved with a little less cooling capacity but with higher total system performance. Series of experiments are conducted with different initial water temperature in tank,compressor load and outdoor ambient temperature conditions. By analysis of transient characteristics and system performance,the performance rules are concluded. Furthermore,the control strategy is proposed to insure the safe and efficient operation of space cooling & water heating mode.
作者 鲁双 吴静怡
出处 《制冷学报》 CAS CSCD 北大核心 2014年第4期1-7,41,共8页 Journal of Refrigeration
基金 国家高技术研究发展计划(863计划 2007AA05Z220)资助项目~~
关键词 家庭能源中心 机组性能系数 控制策略 变容量压缩机 空调 热水 domestic energy system COP control strategy variable capacity compressor air conditioning hot water
  • 相关文献

参考文献17

  • 1Healy C T, Wetherington T I Jr. Water heating by recovery of rejected heat from heat pump [ J ]. ASHRAE Journal, 1965, 4: 68-74.
  • 2Gorzelnik E F. Heat water with your air-conditioner [ J ]. Electrical World, 1977, 188 (11):54-55.
  • 3Ji Jie, Pei Gang, Chow Tin-tai, et al. Performance of multi-functional domestic heat-pump system [ J ]. Applied Energy, 2005, 80(3): 307-326.
  • 4Ji Jie, Chow Tin-tai, Gong Pei, et al. Domestic air-condi- tioner and integrated water heater for subtropical climate [J]. Applied Thermal Engineering, 2003, 23(5) : 581-592.
  • 5Shao Shuangquan, Shi Wenxing, Li Xianting, et al. A new inverter heat pump operated all year round with domes- tic hot water [ J ]. Energy Conversion and Management, 2004, 45(13/14) : 2255-2268.
  • 6Jiang Huimin, Jiang Yiqiang, Wang Yang, et al. An ex- perimental study on a modified air conditioner with a do- mestic hot water supply (ACDHWS) [J]. Energy, 2006, 31(12) : 1789-1803.
  • 7Gong guangcai, Zeng Wei, Wang Liping, et al. A new heat recovery technique for air-conditioning / heat-pump system [J]. Applied Thermal Engineering, 2008, 28 (17/ 18) : 2360-2370.
  • 8Cho Changyong, Choi Jong Min. Experimental investiga- tion of a multi-function heat pump under various operating models [J]. Renewable Energy, 2013, 54: 253-258.
  • 9江乐新,钟杰.空调热水一体机制冷兼制热水模式运行控制策略的研究[J].制冷与空调,2011,11(5):47-49. 被引量:3
  • 10阚安康,韩厚德,陈威.数码涡旋技术在冷藏集装箱上的应用[J].压缩机技术,2005(6):30-33. 被引量:9