家兔右心室异位激动对短时程心脏记忆的影响大于左心室

The impact of RV ectopic excitation on short-term cardiac memory is greater than that of LV in the rabbit
下载PDF
导出
摘要 目的 研究家兔左、右心室异位激动对短时程心脏记忆的影响是否存在差异.方法 记录12只正常成年家兔Ⅱ导联体表心电图;将双极刺激电极分别置于左、右心室前壁游离壁心外膜下,以实现左、右心室分别起搏,模拟左、右心室异位激动;分析异位激动停止后20 min内窦性节律T波的形态和电轴偏转情况,并与起搏前的正常窦性心电图比较,以判断异位激动位置对短时程心脏记忆的影响.结果 左心室异位激动停止后,窦性T波形态基本正常,T波电轴偏转在正常范围内(14°~ 22°).而右心室异位激动停止后,出现T波倒置,与同部位起搏前相比(P<0.05),这种T波倒置在所观察的20 min内持续存在.此外,右心室异位激动停止后,出现T波电轴明显右偏,与同部位起搏前相比(P<0.05),最大右偏角度达127.9°.结论 右心室异位激动后对短时程心脏记忆的影响较大,表现为显著T波倒置和T波电轴右偏,而左心室异位激动对短时程心脏记忆(包括T波形态和T波电轴)的影响不明显. Objective To investigate the differential impact of right versus left ventricular ectopic excitation on the short-term cardiac memory. Methods Surface electrocardiogram (ECG) (Lead Ⅱ ) was recorded and bipolar electrode pacing was performed on the left ventricular (LV) and right ventricular (RV) anterior free walls at an open-chest condition in normal adult rabbits. Within 20 min after pacing, T wave morphology and T wave electrical axis were analyzed and compared with that of the same ventricles before pacing. Results After LV pacing, the T wave morphology was basically normal and the deflection of T axis was within normal range (14° -22°). However, RV pacing resulted in significant T wave inversion and counter-clockwise deflection of T axis ( maximal deflection 127.9°) (P 〈 0. 05 compared with that of the same site before pacing, respectively). Conclusions The influence of RV ectopic excitation on short-term cardiac memory is much greater than that of LV ectopic excitation: RV ectopic excitation induces serious T wave inversion and T axis counter-clockwise deflection, while LV ectopic excitation has no significant influence on T wave morphology and T axis.
出处 《基础医学与临床》 CSCD 北大核心 2014年第8期1049-1053,共5页 Basic and Clinical Medicine
基金 国家级和北京市级大学生创新创业训练计划(201210023060)
关键词 心脏记忆 T波 心脏起搏 异位激动 心电轴 cardiac memory T wave cardiac pacing ectopic excitation cardiac electrical axis
  • 相关文献

参考文献13

  • 1谢德,陈灿,黄石安.心脏记忆及其机制的研究进展[J].心血管病学进展,2011,32(2):272-275. 被引量:5
  • 2Jeyaraj D,Ashwath M,Rosenbaum DS,et al.Pathophysiology and clinical implications of cardiac memory[J].Pacing Clin Electrophysiol,2010,33:346-352.
  • 3Ozgen N,Rosen MR.Cardiac memory:a work in progress[J].Heart Rhythm,2009,6:564-570.
  • 4Patberg KW,Shvilkin A,Plotnikov AN,et al.Cardiac memory:mechanisms and clinical implication[J].Heart Rhythm,2005,12:1376-1382.
  • 5徐春芳,吴杰,陆再英,Jan A.Kors,Peter R.Rijnbeek,G.van Herpen.中国人群心电图T波参数正常范围的调查[J].中国心脏起搏与心电生理杂志,2004,18(5):362-365. 被引量:10
  • 6鲁端,杨莹,韩玲玲,应许青,胡柳琴.健康成人窦性P波、T波、U波额面心电轴的正常参考范围及临床应用[J].心电与循环,2013,32(3):153-156. 被引量:4
  • 7Cardoso CR,Leite NC,Salles GF.Factors associated with abnormal T-wave axis and increased QRS-T angle in type 2 diabetes[J].Acta Diabetol,2013,50:919-925.
  • 8Cowell R,Morris-Thurgood J,Ilsley C,et al.Septal short atriventricular delay pacing:additional hemodynamic improvement in heart failure[J].Pacing Clin Electrophysiol,1994,17:1980-1983.
  • 9Nahlawi M,Waligora M,Spies SM,et al.Left ventricular function during and after right ventricular pacing[J].J Am Coll Cardiol,2004,44:1883-1888.
  • 10Rago L,Di Castelnuovo A,Assanelli D,et al.T-wave axis deviation,metabolic syndrome and estimated cardiovascular risk-in men and women of the MOLI-SANI study[J].Atherosclerosis,2013,226:412-418.

二级参考文献38

  • 1徐春芳,吴杰,陆再英,Jan A.Kors,Peter R.Rijnbeek,G.van Herpen.中国人群心电图T波参数正常范围的调查[J].中国心脏起搏与心电生理杂志,2004,18(5):362-365. 被引量:10
  • 2Wagner GS.Marriott's practical electrocardiography[M].10th ed,Philadelphia:Wolters Kluwer Company,2000.59-60
  • 3Chou TC.Electrocardiography in clinical practice[M].Philadelphia:W.B.Saunders,1996.14-15
  • 4Wu J,Kors JA,Rijnbeek PR,et al.Normal limits of the electrocardiogram in Chinese subjects[J].Int J Cardiol,2003,87:37
  • 5Macfarlane PW,Lawrie TDV.The normal electrocardiogram and vectorcardiogram.In:Macfarlane PW,Lawrie TDV eds.Comprehensive electrocardiology[M].New York:Pergamon Press,1989.407-457
  • 6Van Bemmel JH,Kors JA,Van Herpen G.Methodology of the modular ECG analysis system means[J].Methods Inf Med,1990,29:346
  • 7Willems JL,Abreu-Lima C,Amaud P,et al.The diagnostic performance of computer programs for the interptetation of electrocardiograms[J].N Engl J Med,1991,325:1 767
  • 8The CSE Working Party.Recommendations for measurement standards in quantitative electrocardiography[J].Eur Heart J,1985,6:815
  • 9Cara L,Gambill BA,Michelle L,et al.T wave amplitudes in normal populations variation with ECG lead,sex,and age[J].J Electrocardiol,1995,28:191
  • 10Hayden GE,Brady WJ,Perron AD,et al.Electrocardiographic T-wave Inversion:differential diagnosis in the chest pain patient.Am J Emerg Med,2002,20(3):252-262.

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部