期刊文献+

等离子点火技术在电站锅炉中的应用 被引量:1

Application of Plasma Ignition Technology in the Utility Boiler
下载PDF
导出
摘要 介绍了山西大唐云冈热电公司300MW机组,重点阐述了等离子燃烧器运行调节、点火时的注意事项及运行中故障的排除方法,使锅炉在冷态启动过程中实现无油点火以及满足机组启动升温升压曲线的要求,使电除尘同步投入运行,从而达到环保与节能的目的。 This paper introduces the 300MW unit of Shanxi Datang Yungang Thermal Power Co., Ltd., and expounds the points for attention of the plasma ignition burner operating adjustment and ignition, and the troubleshooting methods in the operation, and it makes the boiler realize oil-free ignition and meet the requirements of unit start-up heating pressure curve in the process of cold starting, which makes the electrostatic precipitation operate synchronously, so as to achieve the goal of environmental protection and energy saving.
作者 曹志伟
出处 《价值工程》 2014年第26期44-45,共2页 Value Engineering
关键词 等离子 应用 调节 注意事项 故障排除方法 plasma application adjust points for attention troubleshooting methods
  • 相关文献

参考文献3

二级参考文献6

  • 1-.DLZ-200型等离子点火装置技术性能考核试验报告[M].国家电力公司热工研究院,2000..
  • 2-.DLZ-200型等离子点煤粉燃烧器工业运行报告[M].烟台发电厂,2000..
  • 3-.DLZ-200型等离子点装置技术及应用[M].烟台龙源电力技术有限公司,2000..
  • 4-.燃煤锅炉启动及稳燃的等离子技术产业化示范工程[M].龙源电力集团公司,2000..
  • 5广东省电力试验研究所.台山电厂3号机组调试报告汇编[R].广州:广东省电力试验研究所,2006.
  • 6张孝勇,陈学渊,罗泽斌,徐海康,李春岩,鞠胤宏.等离子点火技术在烟煤锅炉上的应用[J].中国电力,2002,35(12):15-18. 被引量:47