摘要
通过检查韶关发电厂11号炉屏式过热器的爆漏情况,分析了爆漏原因,研究了解决办法,提出了预防措施,以避免此类事件再次发生。
By examining Shaoguan Power Plant on the 11 th furnace platen superheater leak explosion, analyzed the explosion and leakage of studied solutions proposed preventive measures to avoid recurrence of such incidents.
出处
《科技与创新》
2014年第13期29-30,共2页
Science and Technology & Innovation
关键词
屏式过热器
爆漏
堵塞
监督
platen superheater
burst leakage
jam