介绍了6.3MVA硅铁电炉除尘系统存在的问题及技术改造措施;对新换滤袋使用时间不到两周而全部腐蚀的原因进行了分析;并对低压脉冲袋式除尘器在该炉中的应用情况、控制参数进行了阐述。
The problems existing in dust collec ting equipment of 6.3MVA FeSi electr ic furnace at Wuhan I &S Group Ferroalloy Co.and technical modern ization measures are introduced;th e reasons of all the new filler bag' s corrosion with-in 2weeks are analysed,and the application of low -pressure pulse bag hou se dust collector to the furnace and t he control parameters are also expounded.
出处
《铁合金》
北大核心
2002年第3期16-19,共4页
Ferro-alloys
关键词
硅铁电炉
除尘系统
技术改造
布袋除尘器
FeSi electric furnace,bag house dust collector,technical modernizati on,applicaion