摘要 ITER水平诊断窗口插件是位于ITER装置主机赤道面上的重要装置,用于容纳监测等离子体相关诊断参数的设备和仪器。作为一个系统性工程,ITER设计之初就必须考虑地震事件对整体装置的影响。文中运用三维建模软件CATIA对ITER水平诊断窗口插件进行建模,在ANSYS Workbench采用SMS谱和PALEO谱作为反应谱对窗口插件进行响应谱分析,采用根据ITER的各个不同部位在真空室中的位置,来估算出其受到地震影响时的加速度值的方法进行抗震分析,并对分析结果进行了对比。计算结果均表明,ITER水平诊断窗口插件满足其抗震设计的要求,为整个ITER的设计工作提供了工程理论依据。 ITER Equatorial Port Plug is the core component of diagnostic devices and instrumentations, which is used to observe and measure the parameters of plasma. As a systematic project, at the first in ITER design the impact of seismic events on the overall device had to be considered. The ITER equatorial port plug was modeled by means of using 3D modeling software CATIA. For its seismic analysis, the software ANSYS Workbench was used by means of response spectrum analysis with SMS spectrum and PALEO spectrum and the method based on various parts of the ITER in the vacuum chamber hall position to estimate the value of its acceleration when affected was used. The results of both analysis were compared in the end. The calculations show that tbe ITER equatorial port plug meets the seismic design requirements.
出处 《低温与超导》 CAS 北大核心 2014年第8期43-47,80,共6页 Cryogenics and Superconductivity
关键词 ITER水平诊断窗口插件 抗震分析 响应谱 SMS谱和PALEO谱 ITER Equatorial Port Plug Seismic analysis Response spectrum SMS spectrum and PALEO spectrum
  • 相关文献

参考文献5

二级参考文献25

  • 1张远斌,武松涛,宋云涛,王建青.ITER超导馈线系统的设计[J].核聚变与等离子体物理,2005,25(3):195-199. 被引量:12
  • 2王卿,王佳民,杨朋军.惯性平台框架类结构件的试验模态分析[J].宇航学报,2005,26(6):753-757. 被引量:4
  • 3张远斌,宋云涛,武松涛,王建青.国际热核聚变实验堆过渡馈线设计与分析[J].原子能科学技术,2006,40(3):352-355. 被引量:4
  • 4程亚丽,鲍立曼,宋云涛,姚达毛.EAST超导托卡马克核聚变实验装置真空室窗口烘烤及热应力分析[J].原子能科学技术,2006,40(5):595-598. 被引量:10
  • 5Ioki K. ITER design description document 1.5 vacuum vessel G 15 DDD 4 01-06-25 R0.1 [R]. Germany: ITER Garching Joint Work Site, 2001.1-35,
  • 6Barabash V. ITER materials properties handbook vacuum vessel and in-vessel materials (MPH - IC). G 74 MA 16 04-05-07 R0.1 [R]. Germany: ITER Garching Joint Work Site, 2004. 1-100.
  • 7Verrecchia M. Summary of seismic analyses of tokamak building in the candidate sites: N-S, E-W, vertical direction included. ITER G 73 MD 61 03-10-10 W 0.1 [R]. Germany: ITER Garching Joint Work Site, 2003: 15-21.
  • 8[2]IAEA Safety Standards Series,Safety Guide No.NS-G-3.3.Evaluation of Seismic Hazards for Nuclear Power Plants,2002
  • 9[3]Nucler Safety Commission of Japan.Regulatory Guide for Aseismic Design of Nuclear Power Reactor Facilities,1981
  • 10[4]Daniel Clery.ITER:Stalemate Casts Pall Over Beleaguered Fusion Project.Science,2 April 2004,Vol 304,Issue 5667,26-27

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部