摘要
建立了Salen-Mn(Ⅲ)催化苯乙烯不对称环氧化反应的手性高效液相色谱分析法。采用手性AD-H柱,以正己烷和异丙醇为流动相,207nm作为检测波长,成功分离测定了苯乙烯及其环氧化产物环氧苯乙烷对映异构体。通过实验求得苯乙烯及(R)/(S)-环氧苯乙烷的线性回归方程,其相关系数分别为0.9985、0.9997、0.9995;方法检测限分别为0.02、0.10和0.13μg/mL;该方法低、中、高三个浓度水平的回收率为100.2%~100.8%;相对标准偏差分别为0.86%、1.52%和1.80%。
A chiral HPLC method was developed for the study of asymmetric epoxidation of styrene catalyzed by Salen-Mn( Ⅲ ). The baseline separation of styrene and(R)/(S)-styrene oxide enantiomers was achieved on a chiral AD-H column with n-hexane and isopropanol(99: 1) as the mobile phase at 207 nm. The correlation coefficients were 0. 9985,0. 9997 and 0. 9995 obtained from the linear regression equations of styrene and(R)/(S)-styrene, respectively. The detection limits of styrene and(R)/(S)-styrene were 0.02,0.10 and 0.13μg/mL, respectively. The recoveries of three levels were in the range from 100.2% to 100.8%. And the relative standard deviations were 0.86%, 1.52 G and 1.80%, respectively.
出处
《分析科学学报》
CAS
CSCD
北大核心
2014年第4期569-571,共3页
Journal of Analytical Science
基金
四川省教育厅项目(13ZB0263)
泸州市科技局项目(2011-42)