Two-Phase Flow Pressure Drop of Liquid Nitrogen Boiling in the Straight Section Downstream of U-Bend

Two-Phase Flow Pressure Drop of Liquid Nitrogen Boiling in the Straight Section Downstream of U-Bend
原文传递
导出
摘要 The gas-liquid(two-phase) flow pressure drop of liquid nitrogen boiling in the straight section downstream of U-bend is investigated experimentally. The mass flux ranges from 32 to 280 kg/(m2· s). The inlet pressure of U-tube is from 140 to 272 kPa. And the curvature ratio is from 6.67 to 15. The tube wall including the U-bend is heated uniformly and the heat flux ranges from 0 to 22 kW/m2. The tube with higher inlet pressure has higher pressure drop in the downstream section of the bend. The bended degree of the U-bend influences the pressure drop in the downstream straight section of U-bend. A new correlation taking the effect of the secondary flow into account is proposed for the two-phase slip speed ratio. The pressure drop in the straight section downstream of U-bend calculated by the new correlation agrees well with experimental measurements. The gas-liquid (two-phase) flow pressure drop of liquid nitrogen boiling in the straight section downstream of U-bend is investigated experimentally. The mass flux ranges from 32 to 280 kg/(m2. s). The inlet pressure of U-tube is from 140 to 272 kPa. And the curvature ratio is from 6.67 to 15. The tube wall including the U-bend is heated uniformly and the heat flux ranges from 0 to 22 kW/m2. The tube with higher inlet pressure has higher pressure drop in the downstream section of the bend. The bended degree of the U-bend influences the pressure drop in the downstream straight section of U-bend. A new correlation taking the effect of the secondary flow into account is proposed for the two-phase slip speed ratio. The pressure drop in the straight section downstream of U-bend calculated by the new correlation agrees well with experimental measurements.
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2014年第4期495-501,共7页 上海交通大学学报(英文版)
基金 the National Natural Science Foundation for Young Scholars of China(No.50806042)
关键词 pressure drop downstream of U-bend secondary flow liquid nitrogen pressure drop, downstream of U-bend, secondary flow, liquid nitrogen
  • 相关文献

参考文献11

  • 1WANG C C, CHEN I Y, LIN Y T, et al. A visual ob- servation of the air-water two-phase flow in small di- ameter tubes subject to the influence of vertical return bends [J]. Chemical Engineering Research and Design, 2008, 86(11): 1223-1235.
  • 2PATIL P A, SAPALI S N. Condensation pressure drop of HFC-134a and R-404A in a smooth and micro-fin U-tube [J]. Experimental Thermal and Fluid Science, 2011, 35(1): 234-242.
  • 3ABDULKADIR M, ZHAO D, AzzI A, et al. Two-phase air water flow through a large diameter vertical 180° return bend [J]. Chemical Engineering Science, 2012, 79(10): 138-152.
  • 4DA SILVA LIMA R J, THOME J R. Two-phase flow pat- terns in U-bends and their contiguous straight tubes for different orientations, tube and bend diameters [J]. International Journal of Refrigeration, 2012, 35(5): 1439-1454.
  • 5DA SILVA LIMA R J, THOME J R. Two-phase frictional pressure drops in U-bends and contiguous straight tubes for different refrigerants, orientations, tube, and bend diameters. Part 2. New models (RP-1444) [J]. HVAC & Rresearch, 2012, 18(6): 1072-1097.
  • 6CHEN I Y, WANG C C, LIN Y W. Measurements and correlations of frictional single-phase and two-phase pressure drops of R-410A flow in small U-type re- turn bends [J]. International Journal of Heat and Mass Transfer, 2004, 47(10-11): 2241-2249.
  • 7DOMANSKI P A, HERMES C J L. An improved corre- lation for two-phase pressure drop of R-22 and R-410A in 180° return bends [J]. Applied Thermal Engineering, 2008, 28(7): 793-800.
  • 8PADILLA M, REVELLIN R, BONJOUR J. Two-phase flow visualization and pressure drop measurements of HFO-1234yf and R-134a refrigerants in horizontal re- turn bends [J]. Ezperimental Thermal and Fluid Sci- ence, 2012, 39: 98-111.
  • 9TRAVISS D P, ROHSENOW W M. The influence of re- turn bends on the downstream pressure drop and con- densation heat transfer in tubes [R]. Cambridge, USA: MIT Heat Transfer Laboratory, 1971.
  • 10DE KERPEL K, AMEEL B, HUISSEUNE H, et al. Two- phase flow behaviour and pressure drop of R134a in a smooth hairpin [J]. International Journal of Heat and Mass Transfer, 2012, 55(4): 1179-1188.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部