期刊文献+

A New Method of Combination of Electroosmosis, Vacuum and Surcharge Preloading for Soft Ground Improvement 被引量:21

A New Method of Combination of Electroosmosis, Vacuum and Surcharge Preloading for Soft Ground Improvement
下载PDF
导出
摘要 As a rapid and effective ground improvement method is urgently required for the booming land reclamation in China's coastal area, this study proposes a new combined method of electroosmosis, vacuum preloading and surcharge preloading. A new type of electrical prefabricated vertical drain (ePVD) and a new electroosmotic drainage system are suggested to allow the application of the new method. This combined method is then field-tested and compared with the conventional vacuum combined with surcharge preloading method. The monitoring and foundation test results show that the new method induces a settlement 20% larger than that of the conventional vacuum combined with surcharge preloading method in the same treatment period, and saves approximately half of the treatment time compared with the vacuum combined with surcharge preloading method according to the finite element prediction of the settlement. The proposed method also increases the vane shear strength of the soil significantly. The bearing capacity of the ground improved by use of the new proposed method raises 118%. In comparison, there is only a 75% rise when using the vacuum combined with surcharge preloading method during the same reinforcement period. All results indicate that the proposed combined method is effective and suitable for reinforcing the soft clay ground. Besides, the voltage applied between the anode and cathode increases exponentially versus treatment time when the output current of power supplies is kept constant. Most of the voltage potential in electroosmosis is lost at electrodes, leaving smaller than 50% of the voltage to be effectively transmitted into the soil. As a rapid and effective ground improvement method is urgently required for the booming land reclamation in China's coastal area, this study proposes a new combined method of electroosmosis, vacuum preloading and surcharge preloading. A new type of electrical prefabricated vertical drain (ePVD) and a new electroosmotic drainage system are suggested to allow the application of the new method. This combined method is then field-tested and compared with the conventional vacuum combined with surcharge preloading method. The monitoring and foundation test results show that the new method induces a settlement 20% larger than that of the conventional vacuum combined with surcharge preloading method in the same treatment period, and saves approximately half of the treatment time compared with the vacuum combined with surcharge preloading method according to the finite element prediction of the settlement. The proposed method also increases the vane shear strength of the soil significantly. The bearing capacity of the ground improved by use of the new proposed method raises 118%. In comparison, there is only a 75% rise when using the vacuum combined with surcharge preloading method during the same reinforcement period. All results indicate that the proposed combined method is effective and suitable for reinforcing the soft clay ground. Besides, the voltage applied between the anode and cathode increases exponentially versus treatment time when the output current of power supplies is kept constant. Most of the voltage potential in electroosmosis is lost at electrodes, leaving smaller than 50% of the voltage to be effectively transmitted into the soil.
出处 《China Ocean Engineering》 SCIE EI CSCD 2014年第4期511-528,共18页 中国海洋工程(英文版)
基金 financially supported by the National Natural Science Joint High Speed Railway Key Program Foundation of China(Grant No.U1134207) the Program for Changjiang Scholars and Innovative Research Team in University(Grant No.IRT1125) the Key Science and Technology Program of the Science and Technology Department of Zhejiang Province(Grant No.2009C03001)
关键词 electroosmosis vacuum preloading surcharge preloading soft clay ground electrical resistivity electroosmosis vacuum preloading surcharge preloading soft clay ground electrical resistivity
  • 相关文献

参考文献2

二级参考文献17

  • 1赵维炳,软土固结与流变,1996年
  • 2钱家欢,土工原理与计算,1994年
  • 3赵维炳,河海大学学报,1988年,16卷,5期,96页
  • 4Zeng G X,Proc 8th Asian Regional Conf Soil Mech,1987年,1卷,139页
  • 5Casagrande D R,Casagrande L,Castro G.Improvement of sensitive silty clay by electroosmosis: discussion. Canadian Geotechnical Journal . 1986
  • 6Indraratna B,,Redana I W.Numerical modeling of vertical drains with smear and well resistance installed in soft clay. Canadian Geotechnical Journal . 2000
  • 7Bergado D T,Patawaran M A B.Recent developments of ground improvement with PVD on soft Bangkok clay. Proc. Int. Seminar on Geotechnics . 2000
  • 8Shang J Q,Lo K Y.Electrokinetic dewatering of a phosphate clay. Journal of Hazardous Materials . 1997
  • 9Bergado D T,Manivannan R,Balasubramaniam A S.Proposed criteria for discharge capacity of prefabricated vertical drains. Geotextiles and Geomembranes . 1996
  • 10Morris D V,Hillis S F,Caldwell J A.Improvement of sensitive silty clay by electroosmosis. Canadian Geotechnical Journal . 1985

共引文献133

同被引文献189

引证文献21

二级引证文献330

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部