摘要
通过查找冷却器列管泄漏原因,对设备本体进行解体检查,全面分析了列管泄漏原因,采用新方法 FAT树分析,采取解决途径与预防措施,确保设备稳定可靠运行。
Through tube leakage of the heat exchanger find the cause ,to inspect equipment body with disintegration, comprehensive analysis of the reasons for tube leakage, using a new methods of the FAT tree analysis,take a variety of approaches to solve and preventive measures, ensure stable and reliable operation of equipment.
出处
《中国氯碱》
CAS
2014年第7期27-29,共3页
China Chlor-Alkali
关键词
冷却器
应力腐蚀
电化学腐蚀
液封
FTA树分析
heat exchanger, stress corrosion, electrochemical corrosion, liquid seal, FTA tree analysis.