期刊文献+

某渠道混凝土衬砌底板冻融剥蚀破坏的处理 被引量:1

Treatment for Freeze-thaw Erosion in Concrete Lining Floor of One Open Channel
下载PDF
导出
摘要 在北方冬季最低气温低于零度地区,大中型渠道混凝土衬砌底板部位在施工阶段容易出现冻融剥蚀破坏。结合工程实例,详细介绍了低温地区混凝土剥蚀破坏中冻融破坏的机理和修补方法。混凝土在与水长时间接触后,表层吸水饱和,经过反复冻融循环,出现表层冻融剥蚀破坏,因此,对破坏区域应进行"凿旧补新"修补。聚合物水泥砂浆是一种理想的薄层冻融剥蚀修补材料,当冻融剥蚀破坏深度浅、面积大时,可采用其作为修补材料。 In the north areas where the lowest temperature is below zero in winter,concrete lining floor of large and medium-sized open channel is prone to freeze-thaw erosion during construction.According to actual example,freeze-thaw failure mechanism for concrete freeze-thaw erosion in low temperature area and repair methods are presented in this paper.The surface will absorb water and saturate after concrete contacts with water,then there comes erosion damage after repeated freeze-thaw cycles.The damage areas should be repaired.Polymer cement mortar is a kind of ideal thin layer freeze-thaw erosion repair material.When the freeze-thaw erosion damage area is large and shallow,this can be used as repair material.
作者 侯斌 陈晨
出处 《四川水力发电》 2014年第A01期57-58,共2页 Sichuan Hydropower
关键词 冻融剥蚀 衬砌底板 聚合物砂浆修补 freeze-thaw erosion lining floor polymer mortar repair
  • 相关文献

参考文献1

  • 1黄国兴.水工混凝土建筑物修补技术及应用[M].北京:中国铁道出版社,1992.4-137.

共引文献3

同被引文献2

引证文献1

相关作者