摘要
在常温下用无水乙醇提取玉米中游离脂肪酸,用氢氧化钾标准滴定液滴定,进行脂肪酸值的测定.结果表明,3个不同脂肪酸值的玉米样品13次平行测试的极差最大为1.53 mgKOH/100g,小于重复性临界值2 mgKOH/100g,标准偏差在0.39~0.60.利用该方法对35个样品进行检测,其结果与国标方法平均值之差大于重复性临界值2 mgKOH/100g,建议对国标进行修订.
The method to determine fatty acid value in maize by judging the titration end point is set up.It can be used m deter- mining dissociated fatty acid extracted from maize in normal temperature with the help of anhydrous ethanol and KOH so- lution.The result shows the limit error of three kinds of maize samples which are different in fatty acid content is as follows (during 13 times tests) : maximum error: 1.53 mgKOH/100g〈iterative threshold value : 2 mgKOH/100g.standard deviation: 0.39-0.60(〈1.0).The result of all the 35 samples are transcend 2 mgKOH/100g compared with the detection result based on the national standard method.So the national standard should be revised as soon as possible.
出处
《粮食科技与经济》
2014年第4期35-36,共2页
Food Science And Technology And Economy
关键词
玉米
脂肪酸值
滴定终点
maize, fatty acid value, titration end point