期刊文献+

核分析技术研究一种水系沉积物的多元素取样行为

Study on Sampling Behavior of Multielements for a Stream Sediment Matrix Material With Nuclear Analytical Techniques
下载PDF
导出
摘要 为给研制适用于固体取样微分析质控的天然基体标准物质提供可能的途径,利用3种核分析技术(INAA、PIXE和SRXRF)对自行研制的一种水系沉积物在取样量跨越9个量级(10-1~10-10 g)水平进行多元素取样行为研究。实验结果表明,该基体在不同取样量下,一批元素具有满意的取样不确定度。 For making an effort to explore procedure for development of CRMs for quali-ty control of solid sampling microanalysis , sampling behavior of multielements for a home-made stream sediment matrix material was studied by using three nuclear analyti-cal techniques (INAA ,PIXE and SRXRF ) for sample with size covering 9 orders of magnitude (ranging from 10-1 g to 10-10 g) .It is founded that a series of elements have satisfied sampling behavior on different sampling levels .
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2014年第8期1516-1520,共5页 Atomic Energy Science and Technology
基金 国家自然科学基金资助项目(10575138)
关键词 固体取样微分析 有证标准物质 取样行为 核分析技术 solid sampling microanalysis CRM sampling behavior nuclear analytical technique
  • 相关文献

参考文献12

  • 1ZEISLER R. Reference material for small-sample analysis [J]. Fresenius' Journal of Analytical Chemistry, 1998, 360: 76-379.
  • 2田伟之.反应堆中子活化分析近况(1978-1981).原子能科学技术,1984,(1):113-129.
  • 3TIAN Weizhi, PENG Lixin. A study on sam- pling representativeness of IAEA RM SD-M-2/ TM marine sediment by INAA[J]. Journal of Radioanalytical and Nuclear Chemistry, 1992, 162: 63-70.
  • 4TIAN Weizhi, NI Bangfa, ZHANG Yangmei, et al. Metrological role of neutron activation analysis Ⅲ: Role of INAA in sampling behavior char- acterization[J]. Accreditation and Quality Assur- ance, 2002, 7: 101-105.
  • 5MAO Xueying, CHAI Zhifang. Evaluation of the homogeneity of the environment standard refer- ence material: Esturine sediment SRM 1646 by INAA and SR-XRF[J]. Fresenius' Journal of Analytical Chemistry, 1995, 352: 174-178.
  • 6ZHANG Yuanxun, GU Yingmei, ZHU Xinfang, et al. An investigation of homogeneity within Mi- cro Area of IAEA urban dust reference materials by the scanning proton microprobe technique[J]. Fresenius' Journal of Analytical Chemistry, 1998, 360: 356-358.
  • 7ZEISLER R. NIST SRM 2703 certificate[R/OL]. [2005-09-22]. http: //srmors. nist. gov/view_cert. cfm? srm=2703.
  • 8ROSSBACH M, ZEILLER E. Assessment of el- ement-specific homogeneity in reference materials using microanalytical techniques [J]. Analytical Bioanalytical Chemistry, 2003, 377: 334-339.
  • 9TIAN Weizhi. Nuclear analytical methods in quality control of microanalysis[J]. Journal of Radioanalytical and Nuclear Chemistry, 2004, 262: 223-228.
  • 10HUANG Donghui, XIAO Caijin, NI Bangfa, et al. Characterization of a stream sediment matrix material for sampling behavior in order to use it as a CRM[J]. Applied Radiation and Isotopes, 2010, 68: 37-41.

二级参考文献18

  • 1安丽,曹同,俞鹰浩.苔藓植物与环境重金属污染监测[J].生态学杂志,2006,25(2):201-206. 被引量:39
  • 2田伟之,J Radioanal Nucl Chem,1994年,179卷,1期,119页
  • 3倪邦发,第六届全国活化分析会议论文(摘要)集,1993年
  • 4田伟之,J Radioanal Nucl Chem,1993年,170卷,1期,27页
  • 5潘秀荣,第七次标准物质研讨会论文集,1992年
  • 6倪邦发,核技术,1986年,6卷,41页
  • 7倪邦发,原子能科学技术,1986年,22卷,1期,109页
  • 8田伟之,第一次全国活化分析会议论文集,1981年
  • 9Szczepaniak K, Biziuk M. Environmental Research, 2003, 93:221-230.
  • 10Wolterbeek B. Environ Pollut, 2002, 120:11-21

共引文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部