期刊文献+

A 0.6-V 8.3-ENOB asynchronous SAR ADC for biomedical applications

A 0.6-V 8.3-ENOB asynchronous SAR ADC for biomedical applications
原文传递
导出
摘要 A microwatt asynchronous successive approximation register (SAR) analog-to-digital converter (ADC) is presented. The supply voltage of the SAR ADC is decreased to 0.6 V to fit the low voltage and low power require- ments of biomedical systems. The tail capacitor of the DAC array is reused for least significant bit conversion to decrease the total DAC capacitance thus reducing the power. Asynchronous control logic avoids the high frequency clock generator and further reduces the power consumption. The prototype ADC is fabricated with a standard 0.18 μm CMOS technology. Experimental results show that it achieves an ENOB of 8.3 bit at a 300-kS/s sampling rate. Very low power consumption of 3.04 μW is achieved, resulting in a figure of merit of 32 fJ/conv.-step. A microwatt asynchronous successive approximation register (SAR) analog-to-digital converter (ADC) is presented. The supply voltage of the SAR ADC is decreased to 0.6 V to fit the low voltage and low power require- ments of biomedical systems. The tail capacitor of the DAC array is reused for least significant bit conversion to decrease the total DAC capacitance thus reducing the power. Asynchronous control logic avoids the high frequency clock generator and further reduces the power consumption. The prototype ADC is fabricated with a standard 0.18 μm CMOS technology. Experimental results show that it achieves an ENOB of 8.3 bit at a 300-kS/s sampling rate. Very low power consumption of 3.04 μW is achieved, resulting in a figure of merit of 32 fJ/conv.-step.
出处 《Journal of Semiconductors》 EI CAS CSCD 2014年第8期158-164,共7页 半导体学报(英文版)
基金 Project supported by the Key Science and Technology Innovation Team of Shaanxi Province,China(No.2013KCT-03)
关键词 SAR ADC low voltage low power biomedical system SAR ADC, low voltage low power biomedical system
  • 相关文献

参考文献2

二级参考文献25

  • 1Ginsburg B P, Chandrakasan A E Dual time-interleaved successive approximation register ADCs for ultra-wideband receiver. IEEE J Solid-State Circuits, 2007, 42:247.
  • 2De Man H. Ambient intelligence: gigascale dreams and nanoseale realities. IEEE ISSCC, 2005:29.
  • 3Verma N, Chandrakasan A E An ultra low energy 12-bit rateresolution sealable SAR ADC for wireless sensor nodes. IEEE J Solid-State Circuits, 2007, 42:1196.
  • 4Zhong L, Yang H, Zhang C. Design of an embedded CMOS CR SAR ADC for low power applications in bio-sensor SOC. ASICON. 2007:668.
  • 5Sauebrey J, Schmitt-Landsiedel D, Thewes R. A 0.5-V 1-μW successive approximation ADC. IEEE J Solid-State Circuits, 2003, 38:1261.
  • 6Cho T S, Lee K J, Kong J, et al. A 32-μW 1.83-kS/s carbon nanotube chemical sensor system. IEEE J Solid-State Circuits, 2009, 44:2348.
  • 7Agnes A, Bonizzoni E, Malcovati P, et al. A 9.4-ENOB 1 V 3.8 μW 100 kS/s SAR ADC with time-domain comparator. IEEE ISSCC, 2008:246.
  • 8Baker R J. CMOS circuit design, layout, and simulation. 2nd ed. Hoboken, New Jersey: John Wiley & Sons Inc, 2007:347.
  • 9Eugenio C, Andreou A G. An 8-bit 800-μW 1.23-MS/s successive approximation ADC in SOI CMOS. IEEE Trans Circuits Syst, 2006, 53:858.
  • 10Chang Y K, Wang C S, Wang C K. A 8-bit 500-kS/s low power SAR ADC for bio-medical applications. IEEE ASSCC, 2007:228.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部