摘要
在Fenton基础上加入纳米Fe3O4,在气动超声的条件下处理氯苯废水,并考察了H2O2,纳米Fe3O4,Fe2+,初始pH和反应时间对COD去除率的影响。结果表明,原水pH=3,m(H2O2)∶m(COD)=0.8,n(H2O2)∶n(Fe2+)=10∶1,纳米Fe3O4的投加量为0.05 g时,气动超声时间60 min后,COD的去除率可达到94.5%。
Based on Fenton ,wastewater containing chorobenzene is treated under air ultrasound by nano -Fe3 O4 -Fenton and also the effects of H2 O2 ,nano-Fe3 O4 ,Fe2+ ,initial pH and reaction time on COD removal rate are investigated .The result shows when the raw water pH is 3 .0 ,m(H2O2)∶m(COD) is 0 .8 ,n(H2O2)∶n(Fe2+ ) is 10∶1 and dosage of nano-Fe3 O4 is 0 .05 g ,the removal rate of COD can reach 94 .5% after 60 mins of gas ultrasound reaction time .
出处
《工业安全与环保》
北大核心
2014年第8期83-85,共3页
Industrial Safety and Environmental Protection