摘要 具体介绍了立式油罐和其火灾特点。对国内外关于油罐水喷淋的喷淋强度、喷淋水量及对热辐射的作用的实验研究和数值模拟研究进行归纳,总结出其研究中存在的问题和发展趋势,为以后的研究提出方向。 In this paper ,the characteristics of vertical oil tank and the fires are specifically introduced .The experimental research and simulated modeling studies on oil tank water spray intensity ,spraying water and its effects to thermal radiation at home and abroad are summarized ,the problems existed in the research and development trend has been concluded and it can offer orientation for the following study .
出处 《工业安全与环保》 北大核心 2014年第8期96-98,共3页 Industrial Safety and Environmental Protection
基金 国家自然科学基金(51276024) 江苏省科技支撑计划(BE2012644)
关键词 立式油罐 火灾 水喷淋 冷却 vertical oil tank fire water spray cooling
  • 相关文献

参考文献10

  • 1傅智敏,黄金印.大型地上立式油罐区火灾爆炸危险与灭火救援[J].消防科学与技术,2012,31(7):746-750. 被引量:11
  • 2Roberts TA. Directed deluge system designs and determination of the effectiveness of the currently recommended minimum del- uge rate for the protection of Lt tanks [ J]. Loss Prey Proee Ind, 2004(17) : 103 - 109.
  • 3B Droste, W Schoen. Full scale fire tests with unprotected and thermal imated H:'G storage tanks [ J ]. Journal of Hazardous Materials, 1988(20) :41 - 53.
  • 4Nitesh Jain. Water requirement in tank farm fire[J]. Journal of Petroleum Science and Ee.gineefing, 2007,55:167- 173.
  • 5李建华,黄郑华.油罐火灾沸溢喷溅的控制措施[J].油气储运,2006,25(12):46-48. 被引量:10
  • 6Chow W K, Fong N K. Numerical simulation on cooling of the tlre- induced air flow by sprinkler water sprays[ J ]. Fire Safety Journal, 1991,17(4) :263 - 290.
  • 7Yu N Shebeko, I M Smolin, A Ya Korolchenko. Some aspects of fire and explosiorthnards of large LI storage vellels [ J ]. Loss Prey Process Ind, 1995, ( 8)3 : 163 - 168.
  • 8G F Davies, P F Nolan. Development of a model to predict the effectiveness of existing water deluge systems and to optimise new systems[J]. Journal of Loss Prevention in the Process Indus- tries,2004,17:159 - 168.
  • 9Marco Fossa, Francesco Devia. A model for radiation evaluation and cooling system design in ease of fire in tank farms[J]. Fire Safety Journal,2008,43( 1 ) :42 - 49.
  • 10邢志祥,蒋军成,葛秀坤.液化石油气储罐热响应影响因素模拟分析[J].石油机械,2005,33(4):6-9. 被引量:2

二级参考文献33

  • 1傅智敏,黄金印.南京炼油厂310油罐火灾事故的反思[J].油气储运,1997,16(1):51-53. 被引量:2
  • 2伍作鹏.消防燃烧学[M].北京:中国建筑出版社,1994..
  • 3GB50160-2008,石油化工企业设计防火规范[S].
  • 4GB50183-2004.石油天然气工程设计防火规范[S].[S].,..
  • 5邢志祥 蒋军成.液化气体储罐对火灾的热响应模拟[A]..中国工程热物理学会燃烧学分会2003年学术会议论文集[C].上海,2003.120-128.
  • 6Moodie K, Cowley L T. Fire engulfment tests on a 5 tonne LPG tank, J. of Hazardous Materials, 1988, (20) : 55-71.
  • 7GB50074-2002.石油库设计规范[S].[S].,..
  • 8李建华等:油罐火灾沸溢机理及其预防与扼制技术的研究报告,教育部优秀青年教师资助计划项目,2004.
  • 9Arai M,Saito K et al:A study of boilover in liquid pool fires supported on water,PartⅠ:Effects of a water sublayer on pool fires,Combustion Science and Techology,1990(71).
  • 10Koseki H,Kokkala M,Mulholland G.:Experimental study of boilover in crude oil fires,Proceedings of the 3rd International Symposium on Fire Safety Science,1991.