摘要 目的:建立高效毛细管电泳法测定泰瑞米特钠原料药的含量.方法:以乙酰苯胺为内标;采用石英毛细管拄;运行缓冲液:20 mmol·L-1磷酸二氢钠和10 mmol·L-1十二烷基硫酸钠的混合溶液(pH 6.5);分离电压:20 kV;压力进样:50mbar,5.0s;柱温:20℃;检测波长:245 nm.结果:泰瑞米特钠在0.02~ 1.04 mg·ml-1浓度范围内线性关系良好,r =0.999 9;平均回收率为99.7%(RSD =0.6%,n=9).结论:该方法简便、快速、准确,可控制泰瑞米特钠原料药的质量. Objective: To establish an HPCE method for the content determination of terrymitt sodium crude drug. Methods: Ac- etanilide was used as the internal standard. An uncoated fused silica capillary column was used, the buffer was the mixed solution of 20 mmol · L-l sodium dihydrogen phosphate and 10 mmol ·L-l sodium dodecyl sulfate (pH 6.5 ), the running voltage was 20kV, the sample was injected by pressure at 50mbar in 5s, the column temperature was 20℃ and the detection wavelength was 245nm. Results: The hnear range of terrymitt sodium was 0.02-1.04 mg · ml-1 ( r =0. 999 9 ), the average recovery was 99.7% , and RSD was 0.6% ( n = 9). Conclusion : The method is proved to be simple, rapid and accurate, and can be used in the quality control of terrymitt sodi- um crude drug.
作者 马燕 杨静
出处 《中国药师》 CAS 2014年第8期1331-1333,共3页 China Pharmacist
关键词 泰瑞米特钠 含量测定 高效毛细管电泳法 Terrymitt sodium Determination HPCE