摘要 为实现高盐土壤含水率的精确测量,在室内进行了不同含水率和盐分组合的土柱试验,对TDR探头进行了改进,并利用改进后的TDR测量土壤含水率,同时对结果进行标定。结果表明,改进后的探头能够测量高盐土壤含水率,盐分对改进后TDR的影响表现出与未改进探头不同的规律。Evett模型拟合决定系数为0.835,改进探头含水率测量算法以Evett模型为宜。 To measure soil water content in high salinity soil accurately, indoor soil column experiments with different soil water contents and soil salt contents were conducted. The improved TDR was used to measure soil water content under different conditions and the results were calibrated. The results showed that the improved TDR could well work in higher salinity soil and the influence of salinity on the improved TDR differed from the unimproved TDR. Fitting decision coefficient of Evett model was 0. 835. It is recommended that Evett model should be used for the measurement algorithm of soil moisture by the improved probe.
出处 《灌溉排水学报》 CSCD 北大核心 2014年第4期352-355,共4页 Journal of Irrigation and Drainage
基金 国家自然科学基金项目(51279142 51379151)
关键词 改进 TDR探头 盐分 土壤含水率 标定 improved TDR probe salinity soil water content calibration
  • 相关文献

参考文献9

  • 1Topp G C,Davis J L,Annan A P. Electromagnetic determination of soil water content: Measurements in coaxial transmission lines[J]. Water Resources Research, 1980, 16(3) :574 - 582.
  • 2Skieru W,Wilczek A,Alokhina O. Calibration of a TDR probe for low soil water content measurements[J]. Sensors and Actuators A: Physical, 2008,147 (2) : 544 - 552.
  • 3Zegelin S J,White I, Jenkins D R. Improved field probes for soil-water content and electrical-conductivity measurement using time domain reflectometry[J]. Water Resources Research, 1989,25(11) :2 367 - 2 876.
  • 4谭秀翠,杨金忠,査元源.土壤含盐量对TDR含水率测试结果的影响及校正方法[J].灌溉排水学报,2010,29(6):1-6. 被引量:11
  • 5Pepin S ,Livingston N J, Hook W R . Temperature-dependent measurement errors in time domain reflectometry determinations of soil water[J]. Soil Science Society of America Journal, 1995, 59: 38 - 43.
  • 6Kellner E, Lundin L C. Calibration of time domain reflectometry for water content in peat soil[J]. Nordic Hydrology, 2001,32:315 - 332.
  • 7Evett S R,Tolk J A, Howell T A. Time domain reflectometry laboratory calibration in travel time, bulk electrical conductivity,and effec- tive frequency[J]. Vadose Zone Journal, 2005,4 : 1 020 - 1 029.
  • 8Roth C H,Malicki M A, Plagge R. Empirical-evaluation of the relationship between soil dielectric-constant and volumetric water-content as the basis for calibration soil-moisture measurements by TDR[J]. Journal of Soil Science, 1992,43:1 -13.
  • 9Malicki M A,Plagge R, Roth C H. Improving the calibration of dielectric TDR soil moisture determination taking into account the solid soil[J]. European Journal of Soil Science, 1996,47:357- 366.

二级参考文献8

  • 1Skierucha W, Wilczek A, Alokhina O. Calibration of a TDR probe for low soil water content measurements[J]. Sensors and Actuators A: Physical, 2008,147:544-552.
  • 2Topp G C, Davis J L. Time-domain reflectometry (TDR) and its application to irrigation scheduling[M]// Hillel D. Advances in Irrigation, vol. 3. New York:Academic Press, 1985:107 - 127.
  • 3Noborio K. Measurement of soil water content and electrical conductivity by time domain ret[lectometry: a review [J]. Computers and Electronics in Agriculture, 2001,31 : 213 - 237.
  • 4Zegelin S J, White I, Kenkins D J. Improved field probes for soil water content and electrical conductivity measurement using time domain reflectometry[J]. Water Resource Research, 1989,25:2 367 - 2 376.
  • 5李道西,彭世彰,丁加丽,徐俊增,郁进元.TDR在测量农田土壤水分中的室内标定[J].干旱地区农业研究,2008,26(1):249-252. 被引量:31
  • 6岳英洁,业渝光,刁少波,裴建新,赵广涛.时域反射技术应用与研究新进展[J].海洋湖沼通报,2007(B12):170-175. 被引量:4
  • 7柴世伟,刘文兆,张聚庭.TDR研制与应用方面的若干进展[J].中国生态农业学报,2001,9(2):97-99. 被引量:10
  • 8张智慧,康尔泗,金博文,宋克超.TRIME-TDR技术在黑河流域观测试验中的应用[J].冰川冻土,2003,25(5):574-579. 被引量:12