Proton irradiation effect on SCDs

Proton irradiation effect on SCDs
原文传递
导出
摘要 The Low Energy X-ray Telescope is one of the main payloads on the Hard X-ray Modulation Telescope satellite. Swept charge devices (SCDs) are selected as detectors for the Low Energy X-ray Telescope. As SCDs are sensitive to proton irradiation, irradiation tests were carried out on the HI-13 accelerator at the China Institute of Atomic Energy. The beam energy was measured to be 10 MeV at the SCD. The proton fluence delivered to the SCD was 3×10^8protons/cm2 over two hours. By comparing the performance before and after irradiation, it is concluded that proton irradiation affects both the dark current and the charge transfer inefficiency of the SCD. The energy resolution of the proton-irradiated SCD is 212 eV@5.9 keV at -60℃, while it before irradiated is 134 eV. Moreover, better performance can be reached by lowering the operating temperature of the SCD in orbit. The Low Energy X-ray Telescope is one of the main payloads on the Hard X-ray Modulation Telescope satellite. Swept charge devices (SCDs) are selected as detectors for the Low Energy X-ray Telescope. As SCDs are sensitive to proton irradiation, irradiation tests were carried out on the HI-13 accelerator at the China Institute of Atomic Energy. The beam energy was measured to be 10 MeV at the SCD. The proton fluence delivered to the SCD was 3×10^8protons/cm2 over two hours. By comparing the performance before and after irradiation, it is concluded that proton irradiation affects both the dark current and the charge transfer inefficiency of the SCD. The energy resolution of the proton-irradiated SCD is 212 eV@5.9 keV at -60℃, while it before irradiated is 134 eV. Moreover, better performance can be reached by lowering the operating temperature of the SCD in orbit.
出处 《Chinese Physics C》 SCIE CAS CSCD 2014年第8期60-63,共4页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China(10978002)
关键词 SCD HXMT proton irradiation energy resolution readout noise SCD, HXMT, proton irradiation, energy resolution, readout noise
  • 相关文献

参考文献8

  • 1LIT P. Nuclear Physics B Proceedings Supplements, 2007, 166:131-139.
  • 2Holland A D. Pool P. Proc. of SPIE, 2008, 7021:702117-1.
  • 3Lowe B G. Holland A D, et al. Nuclear Instruments and Meth- ods in Physics Research A, 2001, 458:568-579.
  • 4Smith P H, Gow J P D et al. Proc. of SPIE, 2012, 8453: 84530R-1.
  • 5Janesick J R. Scientific Charge-Coupled Devices, Bellingham, Washington: SPIE Press, 2001. 387 -390.
  • 6WANG Yu-Sa, CHEN Yong, XU Yu-Peng et al. Chinese Physics C (HEP & NP), 2009, 33:1-5.
  • 7Mazziotta M N. Nuclear Instruments and Methods in Physics Research A, 2008, 584:436-439.
  • 8WANG Yu-Sa, YANG Yan-Ji, CHEN Yong et al. Chinese Physics C, 2014, 38:066001.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部