期刊文献+

Simultaneous determination of ezetimibe and simvastatin in rat plasma by stable-isotope dilution LC-ESI-MS/MS and its application to a pharmacokinetic study 被引量:4

Simultaneous determination of ezetimibe and simvastatin in rat plasma by stable-isotope dilution LC-ESI-MS/MS and its application to a pharmacokinetic study
下载PDF
导出
摘要 A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed for simultaneous quantification of ezetimibe and simvastatin in rat plasma. The deuterium isotopes: ezetimibe d4 and simvastatin d6 were used as internal standards for ezetimibe and simvastatin, respectively. MS/MS detection involved a switch of electron spray ionization mode from negative to positive at retention time 3.01 rain. Samples were extracted from plasma by liquid-liquid extraction using tertiary butyl methyl ether. Chromatographic separation was achieved with Agilent Eclipse XBD-CIs column using mobile phase that consisted of a mixture of ammonium acetate (pH4.5; 10 mM)-acetonitrile (25:75 v/v). The method was linear and validated over the concentration range of 0.2--40.0 ng/rnL for simvastatin and 0.05-15.0 ng/mL for ezetimibe. The transitions selected were m/z 408.3→271.1 and m/z 412.0→275.10 for ezetimibe and ezetimibe d4, and m/z 419.30 → 285.20 and rrdz 425.40 →199.20 for simvastatin and simvastatin d6. Intra- and inter-batch precisions for ezetimibe were 1.6-14.8% and 2.1-13.4%; and for simvastatin 0.94-9.56% and 0.79-12%, respectively. The proposed method was sensitive, selective, precise and accurate for the quantification of ezetimibe and simvastatin simultaneously in rat plasma. The method was successfully applied to a pharmacokinetic study by oral co-administration of ezetimibe and simvastatin in SD rats. A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed for simultaneous quantification of ezetimibe and simvastatin in rat plasma. The deuterium isotopes: ezetimibe d4 and simvastatin d6 were used as internal standards for ezetimibe and simvastatin, respectively. MS/MS detection involved a switch of electron spray ionization mode from negative to positive at retention time 3.01 rain. Samples were extracted from plasma by liquid-liquid extraction using tertiary butyl methyl ether. Chromatographic separation was achieved with Agilent Eclipse XBD-CIs column using mobile phase that consisted of a mixture of ammonium acetate (pH4.5; 10 mM)-acetonitrile (25:75 v/v). The method was linear and validated over the concentration range of 0.2--40.0 ng/rnL for simvastatin and 0.05-15.0 ng/mL for ezetimibe. The transitions selected were m/z 408.3→271.1 and m/z 412.0→275.10 for ezetimibe and ezetimibe d4, and m/z 419.30 → 285.20 and rrdz 425.40 →199.20 for simvastatin and simvastatin d6. Intra- and inter-batch precisions for ezetimibe were 1.6-14.8% and 2.1-13.4%; and for simvastatin 0.94-9.56% and 0.79-12%, respectively. The proposed method was sensitive, selective, precise and accurate for the quantification of ezetimibe and simvastatin simultaneously in rat plasma. The method was successfully applied to a pharmacokinetic study by oral co-administration of ezetimibe and simvastatin in SD rats.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第4期286-294,共9页 药物分析学报(英文版)
关键词 EZETIMIBE SIMVASTATIN PharmacokineticsRat plasma LC-ESI-MS/MS Ezetimibe Simvastatin PharmacokineticsRat plasma LC-ESI-MS/MS
  • 相关文献

参考文献1

二级参考文献4

  • 11,Vincent F. Mauro Clin Pharmacokinet, 1993,24(3):195-202
  • 22,Takano T, Abe S, Hata S. Biomed Environ Mass Spectrom,1990,19:577-581
  • 33,Ochiai H, Uchiyama N, Imagaki K et al. J Chromatogr Biomed Appl,1997,694: 2 11-217
  • 44,Carlucci G, Mazzeo P, Biordi L et al. J Pharmaceutical & Biomed Anal, 1992,1 0(9):693-697

共引文献6

同被引文献36

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部