摘要 采用GC900型热解析气相色谱仪,建立了热解析-毛细管气相色谱法测定空气中苯、甲苯、乙酸正丁酯、乙苯、对(间)二甲苯、苯乙烯、邻二甲苯和正十一烷等挥发性有机物的检测方法。这九种挥发性有机物在一定浓度范围内标准曲线线性良好,相关系数均在0.998-0.999之间。本方法在室内空气中TVOC的检测中应用效果良好。 Using thermal desorption gas chromatography by GC900 type,a method for determination of TVOC including benzene,toluene,n- butyl acetate,ethylbenzene,p /m- xylene,styrene,o- xylene and n- undecane using thermal desorption- gas chromatography in air was developed. The related coefficient of standard curves was 0. 998 ~0. 999. Application of this method testing the TVOC was well in indoor air.
作者 王晓明
出处 《广州化工》 CAS 2014年第17期149-151,共3页 GuangZhou Chemical Industry
关键词 热解析 气相色谱法 总挥发性有机物(TVOC) thermal desorption gas chromatography total volatile organic compounds(TVOC)
  • 相关文献

参考文献3

二级参考文献21

  • 1US-EPA:IAQ a Concern in EPA's Planned 232-Million Research Facility. Indoor Air Qualyity Update 9,1996,10:8-13.
  • 2Helsinki FiSIAQ/Finnish Society of Indoor Air Quality and Climate,Finnish Association of Construction Clients/RAKLI, Finnish Association of Architects/SAFA,Finnish Association of Consulting Firms/SKOL. Classification of Indoor Climate, Construction, and Finishing Materials. 1995.
  • 3EU-ECA-WG13. The use of TVOC as an indicator in IAQ investigations. Report of Working Group 13 of European Collaborative Action on Indoor Air Quality and its Impact on Man.JRC,Ispra ,Italy. 1996.
  • 4WHO: Indoor air quality: organic pollutants. Euro Reports and Studies No. 111. World Health Organization, Regional Office for Europe ,Copenhagen. 1989.
  • 5Mφlhave L. :Indoor air quality in relation to sensory irritation due to volatile organic compounds. ASHRAE Trans., 1986 2954, 92(1) ,1-12.
  • 6ENV Ministry of the Environment. Singapore Guidelines for good indoor air quality in office premises, Singapore, 1996.
  • 7EHS Consultants Limited. Final Report : Agreement No. CE 14/95 Consultancy Study on Indoor Air Pollution in Offices and Public Places in Hong Kong.
  • 8Bluyssen P. M. et al. European indoor air quality audit project in 56 office buildings. Indoor Air, 1996,6 : 221-238.
  • 9Brown S. K Assessment and control of volatile organic compounds and house dust mites in Australian buildings. Proceedings of Indoor Air' 96 ,Nagoya,Japan, 1996, (2) :97-102.
  • 10Brown V.M. and Crump D.R. Volatile organic compounds. In:“Indoor Air Quality in Homes: Part 1-The Building Research Establishment Indoor Environment Study”, Building Research Establishment,Watford, 1996,38-66.