期刊文献+

天棚辐射采暖制冷与置换式新风技术的应用

Application of ceiling radiant heating and cooling with replacement fresh air technology
下载PDF
导出
摘要 介绍北京某高档住宅天棚辐射采暖制冷及置换式新风技术的实际应用情况,通过对其冬季采暖热负荷指标、新风热负荷指标以及室内动态热舒适条件进行测试,阐述天棚辐射采暖制冷与置换式新风技术在节能及热舒适度方面的优势。 The practical application of ceiling radiant heating and cooling with replacement fresh air technology to one high-grade residential in Beijing is introduced.Through the test of its winter heating load indicators,fresh air heating load indicators,as well as the indoor dynamic thermal comfort conditions,the advantages of ceiling radiant heating and cooling with replacement fresh air technology in energy-saving and thermal comfort are introduced.
出处 《制冷与空调》 2014年第8期88-92,共5页 Refrigeration and Air-Conditioning
关键词 天棚辐射采暖制冷 置换式新风 舒适度 围护结构 ceiling radiant heating and cooling replacement fresh air degree of com-fort enclosure
  • 相关文献

参考文献7

  • 1张郭阳,尹立明.天棚辐射采暖与制冷系统的安装与维护[J].科技经济市场,2011(3):18-20. 被引量:4
  • 2杨帆,费良斌,李梓铭.顶棚辐射采暖制冷系统末端构造优化方案研究[J].建筑技术,2012,43(7):658-660. 被引量:2
  • 3陆耀庆.实用供热空调设计手册[M]2版.北京:中国建筑工业出版社,2008.
  • 4GB/T7106-2008建设外门窗气密、水密、抗风压性能分级及检测方法[S].
  • 5北京市建筑设计研究院.DBJ11-602-2006居住建筑节能设计标准[S].北京:北京市建筑设计标准化办公室,2007
  • 6ANSI/ASHRAE 55-2004 Thermal Environmental Conditions for Human Occupancy[S].
  • 7ISO 7730-2005 Ergonomics of the thermal enviro- ment-Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria[S].

二级参考文献5

共引文献249