期刊文献+

基于STC89C52便携脉搏测量仪的研制 被引量:7

Development of portable pulse test instrument based on STC89C52
下载PDF
导出
摘要 现在的人们越来越注重自身健康,特别是老年人,他们需要定期体检,但是在医疗水平落后的区域定期体检很难实现。因此文中设计了一款以STC89C52单片机为控制核心,采用HKG-07A红外式脉搏传感器采集数据,通过A/D转换器,送给液晶显示测量结果。经过与医用脉搏测量仪比较,系统具有精度高、性能稳定、反应迅速、性价比高的特点,而且结构简单、使用简洁方便,具有很高的市场价值。 Now people pay more and more attention to their health, especially to old people, they needregular physical examination, but in the area of regular medical examination not developed, which is avery difficult to achieve. Therefore, this paper designed a STC89C52 microcontroller as control core,using HKG-07A infrared pulse sensor data collection, through the A./D converter, for liquid crystaldisplay measurement results. After testing and medical pulse comparison, this system has high accuracy,stable performance, quick response, highratio of performance to price, and has the advantages of simplestructure, the use of simple and convenient, has the very high market value.
作者 白国政
出处 《信息技术》 2014年第8期158-162,共5页 Information Technology
关键词 STC89C52 便携 红外传感 STC89C52 portable infrared sensor
  • 相关文献

参考文献6

二级参考文献12

  • 1徐凯,纪红,乐光新.一种改进的变步长自适应滤波器LMS算法[J].电路与系统学报,2004,9(4):115-117. 被引量:35
  • 2陈阳.脉搏血氧饱和度的局限性[J].国外医学(护理学分册),1997,16(1):6-8. 被引量:6
  • 3张国雄 金篆芷.测控电路[M].北京:机械工业出版社,2000..
  • 4Hayes MJ, Smith PR. Artifact reduction in photoplethysmography [J]. Appl Opt,37(31) :7431 - 7446.
  • 5Swedlow DB. Oximeter with motion detection for alarm modification [P]. International Patent Application WO 94y22360 -13 October 1994.
  • 6Frans M, Coetzee and Ziad Elghazzawi. Noise-Resistant Pulse Oximetry Using a Synthetic Reference Signal[J]. IEEE Trans Biomedical Engineering, 2000, 47(8): 1018- 1026.
  • 7Relente AR, Sison LG. Characterization and adaptive filtering of motion artifacts in pulse oximetry using aceelerometers[ A]. In: The 2nd Joint EMBS/BMES Conference [C]. Houston, TX: IEEE EMBS, 2002. 1769- 1770.
  • 8Stetson PF, Independent component analysis of pulse oximetry signals [A].In: Proceedings of the 26th Annual International Conforence of the IEEE EMBS[C]. San Francisco, CA: IEEE EMBS, 2004. 1 - 5.
  • 9Subramanian H,Ibey BL,Xu Weijian, et al. Real-time separation of perfusion and oxygenation signals for an implantable sensor using adaptive filtering[J]. IEEE Trans Biomedical Engineering,2005,52 (12) :2016 - 2023.
  • 10http ://www. doein.com/p -369274651. html[EB/Z].