期刊文献+

超临界W火焰炉受热面管历次泄漏分析及预防措施

Previous Cause Analysis and Preventive Measures of Supercritical Double Arch Boiler Heating Surface Tube
下载PDF
导出
摘要 通过对某电厂历次受热面管泄漏统计分析,得出该超临界W火焰炉受热面管泄漏次数最多的部件是水冷壁,最主要原因是热负荷输入不均,热应力过大引起的拉裂,因此水冷壁系统的安全运行是该型锅炉运行的关键。本文针对不同原因引起的受热面泄漏进行了分析,并提出了切实可行的预防措施。 By the previous cause analysis of the power plant heating surface tube over the years, the highest number leak component of the heating surface is water wall. The most important reason is excessive crack caused by the uneven heat load input and thermal stress. Therefore, the safe of waterwall system is the key for boiler operation. The different causes of leakage were analyzed. The practicable measures were put forward.
作者 乔立捷
出处 《热加工工艺》 CSCD 北大核心 2014年第16期212-214,共3页 Hot Working Technology
关键词 超临界 W火焰炉 受热面管 泄漏分析 措施 supercriticality W arch boiler heating surface tube failure analysis measures
  • 相关文献

参考文献4

  • 1赵彦华.超临界W火焰锅炉开发研制及技术特点[J].电站系统工程,2012(1):9-12. 被引量:2
  • 2哈尔滨锅炉厂.HG-1900/25.4型超临界直流锅炉说明书[R].2011.
  • 3ASME SA-213/SA-213M-2010 Specification For Seamless fer- ritic and Austenitic Alloy-Steel Boiler,Superheater,and Heat-exchanger Tubes[S].
  • 4GB5310-2008,高压锅炉用无缝钢管[s].

二级参考文献7

共引文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部