基于混凝土损伤塑性模型的自然通风冷却塔非线性抗震分析 被引量:3

Nonlinear Seismic Response of Natural Draft Cooling Tower Based on Concrete Damaged Plasticity Model
原文传递
导出
摘要 为了明确人字型支柱对自然通风冷却塔抗震性能的影响,基于混凝土损伤塑性模型运用通用有限元软件ABAQUS建立了三维实体模型,并考虑了构造配筋,进行地震波作用下的时程分析。通过对冷却塔抗震薄弱部位支柱部分节点拉伸损伤因子的输出统计进行分析,研究不同跨间距和不同支柱对数的人字型支柱对冷却塔结构抗震性能的影响。研究表明:对人字型支柱冷却塔,缩小跨间距有利于提高结构的抗震性能;在不考虑风阻等其他因素时,本研究所选塔型适当增多支柱对数有利于提高结构的抗震性能。 To study the influence of v-frame column support on the seismic performance of natural draft cooling towers, based on the concrete damaged plasticity model, a three-dimensional solid finite element model was built with using the general finite element software ABAQUS, considering the constructional reinforcement. Then the time history analysis under seismic excitation was carried out. The influence of v-frame column supports with different crotch distance and different number of columns on the seismic performance of cooling tower structure was studied, through the analysis on the statistic result of the tensile damage variable of column nodes at seismic weak parts of cooling tower. It is concluded that: for the v- frame column support cooling tower, the seismic performance is promoted while the crotch distance is reduced; it is benefit for the seismic performance by increasing the number of columns, without considering the effects of other factors, such as wind resistance.
出处 《电力建设》 2014年第9期88-92,共5页 Electric Power Construction
基金 国家自然科学杰出青年基金(11025211)
关键词 冷却塔 抗震 混凝土损伤塑性模型 人字型支柱 拉伸损伤因子 cooling tower seismic response concrete damaged plasticity model v-frame column support tensiledamage variable
  • 相关文献

参考文献16

  • 1DL/T 5339—2006 火力发电厂水工设计规范[S].北京:中国电力出版社,2006.
  • 2GB/T 50102—2003 工业循环水冷却设计规范[S]. 北京:中国计划出版社,2003.
  • 3Saeid S G,Farhad A N,Ali R,et al. Numerical study of the nonlinear dynamic behavior of reinforced concrete cooling towers under earthquake excitation[J].Advances in Structural Engineering,2006,9(3):433-441.
  • 4石俊彪. 自然通风冷却塔非线性有限元分析[D].杭州:浙江大学,2008.
  • 5薛文,白国良,姚友成,赵钦.超大型双曲冷却塔考虑不同场地类型的地震性能研究[J].水利与建筑工程学报,2010,8(4):224-226. 被引量:12
  • 6刘明华.双曲线冷却塔结构优化计算与选型[J].电力建设,2000,20(10):35-38. 被引量:28
  • 7孔麟,张美英,戴森,石北啸.间接空冷塔地震反应特性研究[J].电力建设,2013,34(6):60-64. 被引量:4
  • 8Dai J W,Weng X R,Hu Y.Shake table test on the 1∶30 model structure of a large cooling tower for fire power plant[M].Seismic Design of Industrial Facilities,Springer Fachmedien Wiesbaden,2014:281-293.
  • 9Zhu J N,Xu Y Z,Bai G L,et al. Random response analysis of a large-size cooling tower subjected to the stationary earthquake motion[J]. Applied Mechanics and Materials,2013,423:1589-1593.
  • 10李佳颖,任春玲,黄志龙.自然通风冷却塔的实验及有限元分析[J].力学季刊,2007,28(3):443-447. 被引量:27

二级参考文献43

共引文献76

同被引文献25

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部