从机组启动过程、运行控制和汽水品质分析,从理论和试验结果上排除了机组氧化皮脱落是造成高加疏水调节阀堵塞的直接原因,可以为机组的运行和维护起到指导作用。
From the unit starting process, the operational control and the steam water quality analysis, this paper excluded unit oxide skin shedding as the blockage' s direct reason of high pressure normal drain regulating valve based on the theory and experimental result, which will be reference for operation and maintenance of unit..
出处
《贵州电力技术》
2014年第8期11-13,共3页
Guizhou Electric Power Technology
关键词
磁性氧化铁
降噪孔
磁力棒
汽水品质
magnetic iron oxide
noise reduction hole
magnetic rod
steam water quality