期刊文献+

SMILE术后散射的变化特征及相关影响因素 被引量:7

Analysis of stray light changes and relevant factors after SMILE
原文传递
导出
摘要 目的探讨SMILE术后眼内散射的变化,并对其相关影响因素进行分析。方法前瞻性病例研究。选取拟行SMILE手术的近视及近视散光患者67例(67眼),应用C-quant散射仪分别测量患者手术前、术后1周、术后1个月、术后3个月及术后6个月眼内散射光计量值,并与年龄、球镜度、等效球镜度、CCT、角膜平均曲率值(Km)、角膜曲率半径等做相关分析,同时采用Pearson相关分析术后散射光计量值变化与角膜帽直径、小切口大小、切削深度、切削比、剩余角膜厚度(RBT)、RBT/CCT、能量等关系。结果SMILE手术前、术后1周、术后1个月、术后3个月、术后6个月的散射光计量值分别为0.93±0.16、0.97±0.14、0.94±0.17、0.94±0.17、0.90±0.17,术后1周散射光计量值较术前稍增加,但差异无统计学意义,各时间点散射光计量值比较差异无统计学意义(F=2.253,P〉0.05);术后散射光计量值的变化与术中相关参数无明显相关性,仅在术后3个月散射光计量值与切口大小呈较弱正相关(r=0.356,P〈0.01)。结论SMILE术后散射光计量值较术前虽有变化,但变化不明显。术后由散射变化造成视觉质量下降的可能性较小。 Objective To investigate the characteristics and relevant factors of intraocular stray light before and after small incision lenticular extraction (SMILE). Methods In a prospective case study, 67 myopic and myopic astigmatism patients (67 eyes) underwent SMILE surgery in Tianjin Eye Hospital. Stray light measurements were taken before SMILE surgery and 1 week, 1 month, 3 months and 6 months after surgery using an Oculus C-Quant stray light meter. Pearson correlation was used to identify correlations in stray light values for such factors as age, spherical equivalent refractive error, central corneal thickness (CCT), mean keratometric value, and corneal curvature radius as well as for surgical factors such as cap diameter, hinge width, ablation depth, ablation ratio, residual bed thickness, RBT/CCT and energy. Results The stray fight values preoperatively, and 1 week, 1 month, 3 months and 6 months after SMILE surgery were 0.93±0.16, 0.97±0.14, 0.94±0.17, 0.94±0.17, and 0.90±0.17, respectively. The mean stray light value was slightly higher 1 week after surgery but no significant differences were found. There were no significant differences when the various time points were compared (F=2.253, P〉0.05). While the changes in stray light values after surgery were not correlated with surgical parameters, there was a slight positive correlation with hinge width at 3 months after surgery (r=0.356, P〈0.01 ). Conclusion There are no significant differences in stray light between pre- and post-SMILE surgery. It may be possible that a change in stray light could cause a decrease in visual quality.
出处 《中华眼视光学与视觉科学杂志》 CAS 2014年第7期394-398,共5页 Chinese Journal Of Optometry Ophthalmology And Visual Science
基金 基金项目:国家自然科学基金(81170873)
关键词 飞秒激光 飞秒激光小切口基质透镜取出术 散射 视觉质量 Femtosccond laser Small incision lenticule extraction Straylight Visual quality
  • 相关文献

参考文献7

二级参考文献87

  • 1高嵩,张小玲,孙文涛.飞秒激光在基质内屈光手术中的应用[J].国际眼科杂志,2005,5(4):730-733. 被引量:8
  • 2竺向佳,戴锦晖.准分子激光屈光手术上皮下雾状混浊的发生机制[J].国际眼科纵览,2006,30(3):182-186. 被引量:12
  • 3陈冲达,周行涛,戴锦晖,褚仁远,胡敏,于志强,周浩,瞿小妹.微型角膜刀法与乙醇浸润法准分子激光角膜上皮瓣下磨镶术对角膜基质细胞影响的实验研究[J].中华眼科杂志,2006,42(9):796-801. 被引量:30
  • 4Artal P.Understanding aberrations by using double-pass techniques[J].J Refract Surg,2000,16(9):560-562.
  • 5Liang J,Westheimer G.Optical performances of human eyes derived from double-pass measurements[J].J Opt Soc Am A,1995,12(7):1411-1416.
  • 6Williams DR,Brainard DH,Mcmahon MJ.Double-pass and inter ferometric measure of the optical quality of the eye[J].J Opt Soc Am A,1994,11(12):3123-3135.
  • 7Kazuno N,Katsubiko K,Kazuhiko O,et al.Evaluation of optical function using a new point spread function analysissystem in Cataractous and psuedophakic eye:preliminary result[J].Jpn J Ophthalmol,2006,50(1):12-19.
  • 8Kabayashi K,Shibutani M,Takeuchi G,et al.Calculation of ocular single-pass modulation transfer function and retinal image simulation from measurements of the polarized double-pass ocular point spread function[J].J Biomed Opt,2004,9(1):154-161.
  • 9Bellucei R,Morselli S,Piers P.Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses[J].J Refract Surg,2004,20(4):297-306.
  • 10Goodman JW.Introduction to fourier optics[M].San Francisco:Mc GRAN-HILL BOOK COMPANY,1968:18-21.

共引文献123

同被引文献134

  • 1赵军,黄一飞,陈学国,巴恩平.准分子激光屈光性角膜切削术后兔眼角膜组织蛋白多糖的变化[J].军医进修学院学报,2005,26(3):170-171. 被引量:1
  • 2付晶,王军,王宁利,康惠娟.年龄相关性白内障早期视觉功能的临床评价[J].中华眼科杂志,2006,42(3):236-240. 被引量:21
  • 3杨公侠,杨旭东.不舒适眩光与不舒适眩光评价[J].照明工程学报,2006,17(2):11-15. 被引量:32
  • 4徐华斌,吴中林,刘传先,邢冰,陈林.影响人眼视觉质量的光学因素[J].激光生物学报,2007,16(3):271-275. 被引量:4
  • 5王雁,赵堪兴.波前像差与临床视觉矫正[M].北京:人民卫生出版社,2011:41.
  • 6Mello GR, Rocha KM, Santhiago MR, et al. Applications of wavefront technology[J]. J Cataract Refract Surg,2012,38(9): 1671-1683.
  • 7Mok KH, Lee VW. Effect of optical zone ablation diameter on LASIK-induced higher order optical aberrations[J]. J Refract Surg,2005,21 (2) : 141-143.
  • 8Seo KY, Lee JB, Kang JJ, et al. Comparison of higher-order aberrations after LASEK with a 6.0 mm ablation zone and a 6.5 mm ablation zone with blend zone[J]. J Cataract Refract Surg, 2004,30 (3) : 653-657.
  • 9Artal P, Fern6ndez E J, Manzanera S. Are optical aberrations during accommodation a significant problem for refractive surgery?[J]. J Refract Surg,2002,18(5):S563-566.
  • 10Sharma M, Wachler BS, Chan CC. Higher order aberrations and relative risk of symptoms after LASIK[J]. J Refract Surg, 2007,23 (3) : 252-256.

引证文献7

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部