期刊文献+

微切口白内障手术的争论性问题及发展趋势 被引量:4

Analysis of the controversial issues and developing trends in microincision cataract surgery
原文传递
导出
摘要 切口的不断缩小是白内障超声乳化手术发展的趋势.近年来随着手术器械及设备的发展,微切口白内障手术逐渐成为临床医生的首要选择.切口缩小的目的在于更好地提高术中及术后的安全性、更小地改变角膜形态以及使患者更大程度地受益等.作为一项新兴的手术方式,对于微切口白内障手术的最佳手术方式以及最合适切口大小的选择等一系列问题仍存在争议.且随着手术技术、超声乳化设备以及IOL设计的不断进步,特别是飞秒激光在白内障术中的应用日益广泛,未来微切口白内障手术的发展趋势将如何?这一系列问题,值得我们深入探讨. A continuous decrease in incision size has become a significant trend in the development of cataract phacoemulsification surgery.With the advancement of surgical instruments and equipment in recent years,microincision cataract surgery has gradually become the preferred choice for ophthalmic clinicians.The purpose for decreasing incision size is to improve safety during and after surgery,minimize the change in corneal shape,and to benefit patient outcomes.Since this is a newly developing surgical approach,there are still debates on issues regarding the selection of an optimal surgical procedure for microincision cataract surgery and the most suitable incision size.With the continuous improvement in surgical techniques,ultrasound phacoemulsification equipment and the design of intraocular lenses,especially the widely increasing application of femtosecond laser for the treatment of cataract,what will be the developing trends in microincision cataract surgery in the future? This series of questions merits an in-depth discussion.
作者 赵云娥
出处 《中华眼视光学与视觉科学杂志》 CAS 2014年第8期449-451,共3页 Chinese Journal Of Optometry Ophthalmology And Visual Science
基金 国家自然科学基金(81370995) 浙江省自然科学基金(LY12H12004)
关键词 超声乳化白内障吸除术 微切口 显微外科手术 人工晶状体 Phacoemulsification Microincision Microsurgery Intraocular lens
  • 相关文献

参考文献25

  • 1姚克,汤霞靖.微切口白内障超声乳化手术[M]//姚克.微小切口白内障手术学.北京:北京科学技术出版社,2012:156-160.
  • 2Berdahl JP,DeStafeno J J,Kim T.Corneal wound architecture and integrity after phacoemulsification evaluation of coaxial,microincision coaxial,and microincision bimanual techniques[J].J Cataract Refract Surg,2007,33:510-515.
  • 3Wilczynski M,Supady E,Piotr L,et al.Comparison of surgically induced astigmatism after coaxial phacoemulsificalion through 1.8 mm microincision and bimanual phacoemulsificalion through 1.7 mm microincision[J].J Cataract Refract Surg,2009,35:1563-1569.
  • 4Alió JL,Rodriguez-Prats JL,Galal A,et al.Outcomes of microincision cataract surgery versus coaxial phacoemulsification[J].Ophthalmology,2005,112:1997-2003.
  • 5Can I,Bayhan HA,(C)elik H,et al.Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries:a prospective study[J].Curr Eye Res,2012,37:18-24.
  • 6Yu JG,Zhao YE,Shi JL,et al.Biaxial microincision cataract surgery versus conventional coaxial cataract surgery:meta analysis of randomized controlled trials[J].J Cataract Refract Surg,2012,38:894-901.
  • 7Can I,Bayhan HA,Celik H,et al.Anterior segment optical coherence tomography evaluation and comparison of main clear corneal incisions in microcoaxial and biaxial cataract surgery[J].J Cataract Refract Surg,2011,37:490-500.
  • 8Agarwal A,Trivedi RH,Jacob S,et al.Microphakonit:700 micron cataract surgery[J].Clin Ophthalmol,2007,1:323-325.
  • 9Cooper BA,Holekamp NM,Bohigian G,et al.Case-control study of endophthalmitis after cataract surgery comparing scleral tunnel and clear corneal wounds[J].Am J Ophthalmol,2003,136:300-305.
  • 10Monica ML,Long DA.Nine-year safety with self-sealing corneal tunnel incision in clear cornea cataract surgery[J].Ophthalmology,2005,112:985-986.

二级参考文献26

  • 1Kelman CD. Phaco-emulsification and aspiration. A new technique of cataract removal. A preliminary report[J].American Journal of Ophthalmology,1967.23-35.
  • 2Girard LJ. Ultrasonic fragmentation for cataract extraction and cataract complications[J].Advances in Ophthalmology,1978.127-135.
  • 3Agarwal A,Agarwal S. Phakonit-lens removal through a 0.9 mm incision[J].Journal of Cataract and Refractive Surgery,2001.1531-1533.
  • 4Agarwal A,Agarwal S. Phakonit:phacoemulsification through a 0.9 mm corneal incision[J].Journal of Cataract and Refractive Surgery,2001.1548-1552.
  • 5Tsuneoka H,Shiba T,Takahashi Y. Feasibility of ultrasound cataract surgery with a 1.4 mm incision[J].Journal of Cataract and Refractive Surgery,2001.934-940.
  • 6Donnenfeld ED,Olson RJ,Solomon R. Efficacy and wound-temperature gradient of whitestar phacoemulsification through a 1.2 mm incision[J].Journal of Cataract and Refractive Surgery,2003.1097-1100.
  • 7Braga-Mele R,Liu E. Feasibility of sleeveless bimanual phacoemulsification with the Millennium microsurgical system[J].Journal of Cataract and Refractive Surgery,2003,(11):2199-2203.doi:10.1016/S0886-3350(03)00330-4.
  • 8Akahoshi T. Farewell to bimanual;developing a sub-2-mm coaxial phaco and IOL insertion technique[J].Cataract and Refractive Surgery Today,2005,(suppl):5-8.
  • 9Cavallini GM,Campi L,Masini C. Bimanual microphacoemulsification versus coaxial miniphacoemulsification:Prospective study[J].Journal of Cataract and Refractive Surgery,2007.387-392.
  • 10Kurz S,Krummenauer F,Thieme H. Biaxial microincision versus coaxial small-incision cataract surgery in complicated cases[J].Journal of Cataract and Refractive Surgery,2010.66-72.doi:10.1016/j.jcrs.2009.07.036.

共引文献6

同被引文献54

  • 1王雨晴,王林,张招德.小切口非超声乳化白内障手术治疗硬核白内障的临床效果研究[J].哈尔滨医科大学学报,2023,57(1):41-45. 被引量:3
  • 2World Health Organization.Global data on visual impairment 2010[EB/OL]. [2016-01-11]. http://www.who.int/blindness/publications/globaldata/en.
  • 3McCarthyM, GavanskiGM, PatonKE, et al.Intraocular lens power calculations after myopic laser refractive surgery:a comparison of methods in 173 eyes[J]. Ophthalmology, 2011, 118 (5):940-944.DOI:10.1016/j.ophtha.2010.08.048.
  • 4JonasJB, NangiaV, GuptaR, et al.Anterior chamber depth and its associations with ocular and general parameters in adults[J]. Clin Exper Ophthalmol, 2012, 40(6):550-556.DOI:10.1111/j.1442-9071.2011.02748.x.
  • 5ShentuX, ZhangX, TangX, et al.Coaxial microincision cataract surgery versus standard coaxial small-incision cataract surgery:A Meta-analysis of randomized controlled trials[J/OL]. PLoS One, 2016, 11(1):e0146676[2016-01-10]. http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0146676.
  • 6CanI, BayhanHA, CelikH, et al.Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries:a prospective study[J]. Curr Eye Res, 2012, 37(1):18-24.DOI:10.3109/02713683.2011.622851.
  • 7CavalliniGM, VolanteV, VerdinaT, et al.Results and complications of surgeons-in-training learning bimanual microincision cataract surgery[J]. J Cataract Refract Surg, 2015, 41(1):105-115.DOI:10.1016/j.jcrs.2014.04.034.
  • 8ChenC, ZhuM, SunY, et al.Bimanual microincision versus standard coaxial small-incision cataract surgery:meta-analysis of randomized controlled trials[J]. Eur J Ophthalmol, 2015, 25(2):119-127.DOI:10.5301/ejo.5000521.
  • 9AuffarthGU, ReddyKP, RitterR, et al.Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy[J]. J Cataract Refract Surg, 2013, 39(1):105-109.DOI:10.1016/j.jcrs.2012.08.065.
  • 10KranitzK, TakacsA, MihaltzK, et al.Femtosecond laser capsulotomy and manual continuous curvilinear capsulorrhexis parameters and their effects on intraocular lens centration[J]. J Refract Surg, 2011, 27(8):558-563.DOI:10.3928/1081597X-20110623-03.

引证文献4

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部