期刊文献+

硬膜外预充生理盐水预防剖宫产术中硬膜外置管诱发血管损伤的临床观察 被引量:14

下载PDF
导出
摘要 足月妊娠产妇因增大的子宫压迫下腔静脉,促使硬膜外静脉丛血流增加,血管扩张,穿刺针和导管可直接损伤硬膜外血管.剖宫产产妇硬膜外置管损伤血管或误入静脉的发生率为1.3%~15.7%,置管损伤血管后可直接导致局麻药毒性反应,麻醉效果欠佳,甚至发生硬膜外血肿和严重的神经并发症.本研究观察硬膜外预充生理盐水用于预防剖宫产术中硬膜外置管时对血管损伤的影响.
出处 《临床麻醉学杂志》 CAS CSCD 北大核心 2014年第8期820-821,共2页 Journal of Clinical Anesthesiology
  • 相关文献

参考文献4

二级参考文献20

  • 1Miller.米勒著麻醉学中文版.曾因明,邓小明,黄宇光,译.北京:北京大学医学出版社,2006.
  • 2Evron S,Sessler D,Sadan O,et al.Identification of the epidural space:loss of resistance with air,lidocaine,or the combination of air and lidocaine.Anesth Analg,2004,99(1):245-250.
  • 3Takiguchi T,Okano T,Egawa H,et al.The effect of epidural saline injection on analgesic level during combined spinal and epidural anesthesia assessed clinically and myelographically.Anesth Analg,1997,85(5):1097-1100.
  • 4Roberts SA,Gumswamy V,Galvez I.Caudal injectate can be reliably imaged using portable ultrasound--a preliminary study.Paediatr Anaesth,2005,15(11):948-952.
  • 5窦元元 刘峥.经硬膜外腔监测脑脊液压的临床应用[J].临床麻醉杂志,1996,.
  • 6Christie IW,McCabe S.Major complications of epidural analgesia after surgery:results of a six-year survey.Anaesthesia,2007,62(4):335-341.
  • 7Cameron CM,Scott DA,McDonald WM,et al.A review of neuraxial epidural morbidity:experience of more than 8,000cases at a single teaching hospital.Anesthesiology,2007,106(5):997-1002.
  • 8P(o)pping DM,Zahn PK,Van Aken HK,et al.Effectiveness and safety of postoperative pain management:a survey of 18925consecutive patients between 1998 and 2006 (2nd revision):a database analysis of prospectively raised data.Br J Anaesth,2008,101(6):832-840.
  • 9Barash P G,Cullen B F,Stoelting R K.床麻醉学.王伟鹏,李立环,主译.第4版.北京:人民卫生出版社,2004:612-613.
  • 10Hughes S C,Levinson G,Rosen M A.施奈德与莱文森产科麻醉学.张友忠,荣风年,主译.第4版.山东:科学技术出版社,2005:376-456.

共引文献13

同被引文献64

  • 1吴敏仙,唐新龙.剖宫产术病人左旋布比卡因、罗哌卡因及布比卡因硬膜外麻醉的效果[J].中华麻醉学杂志,2006,26(2):176-177. 被引量:20
  • 2Wang C, Slikker W. Strategies and experimental models for evaluating anesthetics: effects on the developing nervous system[J]. Anesth Analg, 2008, 106(6): 1643-1658.
  • 3Miller RD, Miller's Anesthesia [M]. 7th ed. New York: Churchill livingstone, 2010: 769-824.
  • 4Leo S, Sng BL, Lim Y, et al. A randomized comparison of low doses of hyperbaric bupivacaine in combined spinal-epidural anesthesia for cesarean delivery[J]. Anesth Analg, 2009, 109(5): 1600-1605.
  • 5于布为,刘进,吴新民’等.中国麻醉学指南与专家共识[M].北京:人民卫生出版社,2014:119-126.
  • 6Kjaer MM, Lauenborg J, Breum BM, et al. The risk of adverse pregnancy outcome after bariatric surgery: a nationwide register-based matched cohort study[J]. Am J Obstet Gynecol, 2013, 208(6): 464.e1-464.e5.
  • 7Benhamou D, Wong C. Neuraxial anesthesia for cesarean delivery: what criteria define the "optimal" technique?[J]. Anesth Analg, 2009, 109(5): 1370-1373.
  • 8Teoh WH, Thomas E, Tan HM. Ultra-low dose combined spinal- epidural anesthesia with intrathecal bupivacaine 3.75 mg for cesarean delivery: a randomized controlled trial[J]. Int J Obstet Anesth, 2006, 15(4): 273-278.
  • 9Mhyre ]M, Greenfield ML, Tsen LC, et al. A systematic review of randomized controlled trials that evaluate strategies to avoid epidural vein cannulation during obstetric epidural catheter placement[J]. Anesth Analg, 2009, 108(4): 1232-1242.
  • 10Delamarter RB, Sherman J, Carr JB. Pathophysiology of spi- nal cord injury. Recovery after immediate and delayed decom- pression. J Bone Joint Surg Am, 1995,77 (7) : 1042-1049.

引证文献14

二级引证文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部